--- a/emailservices/emailservermonitor/inc/emailshutdownconst.h Fri May 28 13:56:43 2010 +0300
+++ /dev/null Thu Jan 01 00:00:00 1970 +0000
@@ -1,79 +0,0 @@
-/*
-* Copyright (c) 2009 Nokia Corporation and/or its subsidiary(-ies).
-* All rights reserved.
-* This component and the accompanying materials are made available
-* under the terms of "Eclipse Public License v1.0"
-* which accompanies this distribution, and is available
-* at the URL "http://www.eclipse.org/legal/epl-v10.html".
-*
-* Initial Contributors:
-* Nokia Corporation - initial contribution.
-*
-* Contributors:
-*
-* Description:
-* Constant definitions for Email shutdown
-*
-*/
-
-#ifndef EMAILSHUTDOWNCONST_H
-#define EMAILSHUTDOWNCONST_H
-
-#include <e32cmn.h> // TUid
-#include "emailshutdownconst.hrh" // KEmailShutdownUidAsTInt
-
-
-// Publish & Subscribe category for Email shutdown events
-const TUid KEmailShutdownPsCategory = { KEmailShutdownUidAsTInt };
-
-// Size of one item in platform API UID list (in Publish & Subscribe
-// key EEmailPsKeyPlatformApiAppsToClose)
-const TInt KEmailPlatformApiUidItemSize = sizeof( TInt32 );
-
-// Publish & Subscribe keys used in shutdown process
-enum TEmailShutdownPsKeys
- {
- // Publish & Subscribe key used in communication between Shutter
- // application and installation initiators
- EEmailPsKeyInstallationStatus = 1,
-
- // Publish & Subscribe keys for Email shutdown events
- EEmailPsKeyShutdownClients,
- EEmailPsKeyShutdownPlugins,
- EEmailPsKeyShutdownMsgStore,
-
- // Publish & Subscribe keys to register 3rd party applications to be closed
- EEmailPsKeyPlatformApiAppsToCloseLength,
- EEmailPsKeyPlatformApiAppsToClose
- };
-
-// Publish & Subscribe values to be used with key EEmailPsKeyInstallationStatus
-enum TEmailShutdownPsInstallationValues
- {
- // Value to be set by installation initiators when installation is starting
- EEmailPsValueInstallationStarting = 1,
- // Value to be set by Shutter when all services are shutdown
- EEmailPsValueInstallationOkToStart,
- // Value to be set by installation initiators when installation is started
- // after EEmailPsValueInstallationOkToStart event received
- EEmailPsValueInstallationStarted,
- // Value to be set by Starter when installation has finished
- EEmailPsValueInstallationFinished
- };
-
-// Executable name of the process that implements the shutdown functionality
-_LIT( KEmailShutdownHandlerExe, "emailservermonitor.exe" );
-
-// Command line arguments that can be given to shutdown handler process when
-// starting it
-
-// KEmailShutdownHandlerArgOnlyShutter should be used when starting the process
-// just before starting installation (if it wasn't already running)
-_LIT( KEmailShutdownHandlerArgOnlyShutter, "OnlyShutter" );
-
-// KEmailShutdownHandlerArgRestart should be given when restarting
-// the process after installation
-_LIT( KEmailShutdownHandlerArgRestart, "RestartAfterInstallation" );
-
-
-#endif // EMAILSHUTDOWNCONST_H