secureswitools/swisistools/test/tinterpretsisinteg/api-inst-testcase-interpretsis-09_db.bat
changeset 75 2d2d25361590
--- /dev/null	Thu Jan 01 00:00:00 1970 +0000
+++ b/secureswitools/swisistools/test/tinterpretsisinteg/api-inst-testcase-interpretsis-09_db.bat	Tue Sep 28 14:48:39 2010 +0300
@@ -0,0 +1,53 @@
+@rem
+@rem Copyright (c) 2009 Nokia Corporation and/or its subsidiary(-ies).
+@rem All rights reserved.
+@rem This component and the accompanying materials are made available
+@rem under the terms of "Eclipse Public License v1.0"
+@rem which accompanies this distribution, and is available
+@rem at the URL "http://www.eclipse.org/legal/epl-v10.html".
+@rem
+@rem Initial Contributors:
+@rem Nokia Corporation - initial contribution.
+@rem
+@rem Contributors:
+@rem
+@rem Description:
+@rem
+@ECHO OFF
+REM testcase-interpretsis-08
+REM testcase testcase-interpretsis-08 - Verify if ROM SIS STUB and Pre-Provisioned registration files are processed. This is a positive testcase 
+
+if not exist .\cdrive mkdir .\cdrive > NUL
+if not exist .\romdrive mkdir .\romdrive > NUL
+if not exist .\romdrive\system mkdir .\romdrive\system > NUL
+if not exist .\romdrive\system\install mkdir .\romdrive\system\install > NUL
+
+REM xcopy /E /Y backup\cdrive cdrive > NUL
+REM xcopy /E /Y backup\romdrive romdrive > NUL
+
+
+REM Remove installation files from any previous tests
+if exist  .\cdrive\Documents\InstTest\devlangsup*.txt  del .\cdrive\Documents\InstTest\devlangsup*.txt  > NUL
+if not exist .\romdrive\sys\install\scr\provisioned mkdir .\romdrive\sys\install\scr\provisioned > NUL
+if exist  .\romdrive\sys\install\scr\provisioned\scr.db  del .\romdrive\sys\install\scr\provisioned\scr.db  > NUL
+copy \epoc32\release\winscw\udeb\z\sys\install\scr\provisioned\scr.db .\romdrive\sys\install\scr\provisioned\scr.db /Y > NUL
+
+REM call scrtool -d \epoc32\release\winscw\udeb\z\sys\install\scr\provisioned\scr.db -p \epoc32\winscw\c\tswi\tinterpretsisinteg\preprovision_appproperty_opaquedata.xml > NUL
+call scrtool -d .\romdrive\sys\install\scr\provisioned\scr.db -p \epoc32\winscw\c\tswi\tinterpretsisinteg\preprovision_appproperty_opaquedata.xml > NUL
+
+if not exist \epoc32\winscw\c\sys\install\scr mkdir \epoc32\winscw\c\sys\install\scr > NUL
+if exist  \epoc32\winscw\c\sys\install\scr\scr.db  del \epoc32\winscw\c\sys\install\scr\scr.db  > NUL
+copy .\romdrive\sys\install\scr\provisioned\scr.db \epoc32\winscw\c\sys\install\scr\scr.db /Y > NUL
+
+IF NOT EXIST .\backup\cdrive mkdir .\backup\cdrive > NUL
+IF NOT EXIST .\backup\romdrive mkdir .\backup\romdrive > NUL
+xcopy /E /Y cdrive backup\cdrive > NUL
+xcopy /E /Y romdrive backup\romdrive > NUL
+
+IF NOT %errorlevel%==0 GOTO LAST
+ECHO ***ERRORCODE*** %errorlevel% PASS>>/epoc32/winscw/c/interpretsis_test_harness_db.txt
+GOTO END
+:LAST
+ECHO ***ERRORCODE*** %errorlevel% FAIL>>/epoc32/winscw/c/interpretsis_test_harness_db.txt
+:END
+