// graphics-wserv-integ-dsa.script
//
// Tests Public elements of the DSA class
// as a means of confidence that the APIs work as expected.
//
// The purpose is to provide a regression test suite of Public
// APIs for DSA. Negative testing is performed to confirm that correct
// errors are returned when incorrect parameters are given.
//
// The tests are fully automated.
/////////////////////////////////////////////////////////////////////
LOAD_SUITE t_wservintegserver
//! @file
//! @SYMTestSuiteName graphics-wserv-integ-dsa
//! @SYMScriptTestEnvironment This test script requires a modified ROM, which replaces
//! the default wsini.ini with wsini_dsa_h6.ini.
START_TESTCASE GRAPHICS-WSERV-INTEG-DSA-0001-0002
//! @SYMTestCaseID GRAPHICS-WSERV-INTEG-DSA-0001-0002
//! @SYMPREQ 1007 1019
//! @SYMREQ 8222 8223 8227
//! @SYMAPI DSA
//! @SYMAuthor Andy Kinney
//! @SYMCreationDate 16/03/2007
//! @SYMTestCaseDependencies setup-graphics-wserv-integ-dsa.script wsini_dsa.ini
//! @SYMTestCaseDesc Check DSA app is aborted when screen rotated
//! @SYMTestActions 1. Start non-DSA app (t_app1.exe)
//! 2. Start DSA app (t_dsaapp.exe)
//! 3. t_dsaapp draws to top half of screen
//! red/green alternate frames
//! 4. t_app1 rotates screen to 0 after (dummy rotation since 90 degree not supported on H6)
//! number of iterations divided by number of rotations
//! 5. t_dsaapp reaches last iteration and writes result file
//! 6. TEF Step code reads result file and checks for expected
//! values, and reports pass or fail
//! @SYMTestStatus Implemented
//! @SYMTestPriority Critical
//! @SYMTestExpectedResults The screen does not rotate and no panics are generated. Top half of screen is displaying
//! alternate frames of green and blue. DSA App does not count any abort requests
/! @SYMTestType CIT
RUN_TEST_STEP 180 t_wservintegserver WServIntegDsa c:\graphics\graphics-wserv-integ-dsa.ini graphics-wserv-integ-dsa-0001-002
END_TESTCASE GRAPHICS-WSERV-INTEG-DSA-0001-0002