--- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/lbstest/lbstestproduct/lbsx3p/scripts/lbsx3pcancel.script Tue Feb 02 01:50:39 2010 +0200
@@ -0,0 +1,341 @@
+// Copyright (c) 2006-2009 Nokia Corporation and/or its subsidiary(-ies).
+// All rights reserved.
+// This component and the accompanying materials are made available
+// under the terms of "Eclipse Public License v1.0"
+// which accompanies this distribution, and is available
+// at the URL "http://www.eclipse.org/legal/epl-v10.html".
+//
+// Initial Contributors:
+// Nokia Corporation - initial contribution.
+//
+// Contributors:
+//
+// Description:
+//
+
+LOAD_SUITE LbsX3PTestServer -SharedData
+
+PRINT Run LbsX3PTestServer
+PRINT
+
+// Before we start LBS, select the test A-GPS integration module and network reg status txt file to use.
+PREFIX RUN_UTILS
+ MkDir c:\private\10282253\
+ MkDir c:\private\10282253\lbs\
+ MkDir c:\private\10282253\lbs\locmods\
+ CopyFile c:\testdata\configs\xtestmodule.ini c:\private\10282253\lbs\locmods\agpsintegmodule.ini
+ CopyFile c:\testdata\configs\lbstestconfig.txt c:\config.txt
+REMOVE_PREFIX
+
+PRINT Start LBS
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_ResetDefaultAdmin
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_StartLbs
+
+START_TESTCASE LBS-X3P-Cancel-0001
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0001
+//!@SYMTestCaseDesc Call RlbsTransmitPosition::CancelTransmitPosition() when no transmit is outstanding.
+//!
+//!@SYMTestActions 1. Open sub-session
+//! 2. Do not request X3P
+//! 3. Attempt to cancel X3P
+//!
+//!@SYMTestExpectedResults CancelTransmitPosition() fails with KErrNotFound
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 2
+//!@SYMTestStatus Not Implemented
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 060 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0001
+
+END_TESTCASE LBS-X3P-Cancel-0001
+
+
+START_TESTCASE LBS-X3P-Cancel-0002
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0002
+//!@SYMTestCaseDesc Request X3P, then cancel request before MO-LR started ()
+//!
+//!@SYMTestActions 1. Open a session with the transmit position server
+//! 2. Create a sub-session
+//! 3. Request current position be sent to a third party � RlbsTransmitPosition::TransmitPosition()
+//! giving a valid destination Id (email/phone number).
+//! 4. RLbsTransmitPosition::CancelTransmitPosition()
+//! 5. Wait for request to complete
+//!
+//!@SYMTestExpectedResults No panic. X3P request completes with KErrCancel
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 2
+//!@SYMTestStatus Not Implemented
+
+// May not be possible to implement. Need to get the cancel in after the NRH sends the request to the NG,
+// but before the protocol module sends the MOLR to the network.
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 060 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0002
+
+END_TESTCASE LBS-X3P-Cancel-0002
+
+
+START_TESTCASE LBS-X3P-Cancel-0003
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0003
+//!@SYMTestCaseDesc Request X3P, then cancel request before MO-LR started ()
+//!
+//!@SYMTestActions 1. Tell NetSim that next request should have a time delay (needed)
+//! 2. Request current position be sent to a third party � RlbsTransmitPosition::TransmitPosition()
+//! 3. Wait for notification from NetSim that MOLR has been sent
+//! 4. RLbsTransmitPosition::CancelTransmitPosition()
+//!
+//!@SYMTestExpectedResults No panic. X3P request completes with KErrNone or KErrCancel in CActive::Cancel()
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 1
+//!@SYMTestStatus Not Implemented
+
+// ISSUE: Jarek mentioned using the timelag feature in NetSim for the MOLR, but not sure why that would be needed?
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 060 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0003
+
+END_TESTCASE LBS-X3P-Cancel-0003
+
+
+START_TESTCASE LBS-X3P-Cancel-0004
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0004
+//!@SYMTestCaseDesc Request X3P, then cancel request after location request received
+//!
+//!@SYMTestActions 1. Request current position be sent to a third party � RlbsTransmitPosition::TransmitPosition()
+//! 2. Wait for notification of Location Request from network (sent in response to MOLR)
+//! 3. RLbsTransmitPosition::CancelTransmitPosition()
+//!
+//!@SYMTestExpectedResults No panic. X3P request completes with KErrNone or KErrCancel in CActive::Cancel()
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 1
+//!@SYMTestStatus Not Implemented
+
+// ISSUE: Jarek mentioned using the timelag feature in NetSim for the MOLR, but not sure why that would be needed?
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 060 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0004
+
+END_TESTCASE LBS-X3P-Cancel-0004
+
+
+START_TESTCASE LBS-X3P-Cancel-0005
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0005
+//!@SYMTestCaseDesc Request X3P, then cancel request after responding to location request
+//!
+//!@SYMTestActions 1. Request current position be sent to a third party � RlbsTransmitPosition::TransmitPosition()
+//! 2. Wait for notification of response to Location Request from network
+//! 3. RLbsTransmitPosition::CancelTransmitPosition()
+//!
+//!@SYMTestExpectedResults No panic. X3P request completes with KErrNone or KErrCancel in CActive::Cancel()
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 1
+//!@SYMTestStatus Not Implemented
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 060 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0005
+
+END_TESTCASE LBS-X3P-Cancel-0005
+
+
+START_TESTCASE LBS-X3P-Cancel-0006
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0006
+//!@SYMTestCaseDesc Request X3P, then cancel request after protocol module closed MOLR but before it sent X3P complete to NRH
+//!
+//!@SYMTestActions 1. Request current position be sent to a third party � RlbsTransmitPosition::TransmitPosition()
+//!
+//!@SYMTestExpectedResults No panic. X3P request completes with KErrNone or KErrCancel in CActive::Cancel()
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 1
+//!@SYMTestStatus Not Implemented
+
+// ISSUES: Currently not possible to implement. Think it would require new functionality (to insert a time lag) in NetSim
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 060 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0006
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_VerifyPosInfos
+
+END_TESTCASE LBS-X3P-Cancel-0006
+
+
+START_TESTCASE LBS-X3P-Cancel-0007
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0007
+//!@SYMTestCaseDesc
+//!
+//!@SYMTestActions 1. Request current position be sent to a third party - RlbsTransmitPosition::TransmitPosition()
+//! 2. Try to cancel Active object using Cancel function and in the cancel function call CancelTransmitPostion()
+//!
+//!@SYMTestExpectedResults TransmitPosition should be canceled without any problem
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 1
+//!@SYMTestStatus Not Implemented
+
+// ISSUES: Currently not possible to implement. Think it would require new functionality (to insert a time lag) in NetSim
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 060 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0007
+
+END_TESTCASE LBS-X3P-Cancel-0007
+
+
+START_TESTCASE LBS-X3P-Cancel-0008
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0008
+//!@SYMTestCaseDesc
+//!
+//!@SYMTestActions 1. Create two transmit Positional objects
+//! 2. Call TransmitPosition from the first one
+//! 3. Try canceling on the second TransmitPosition object
+//!
+//!@SYMTestExpectedResults Transmit Postion should complete properly on first one. Cancel on second one should not have any effect
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 1
+//!@SYMTestStatus Not Implemented
+
+// ISSUES: Currently not possible to implement. Think it would require new functionality (to insert a time lag) in NetSim
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 060 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0008
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_VerifyPosInfos
+
+END_TESTCASE LBS-X3P-Cancel-0008
+
+
+START_TESTCASE LBS-X3P-Cancel-0009
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0009
+//!@SYMTestCaseDesc
+//!
+//!@SYMTestActions 1. Create two transmit Positional objects
+//! 2. Call TransmitPosition from the first one
+//! 3. Try canceling on the second TransmitPosition object using Active Object->Cancel() function
+//!
+//!@SYMTestExpectedResults Transmit Postion should complete properly on first one. Cancel on second one should not have any effect
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 1
+//!@SYMTestStatus Not Implemented
+
+// ISSUES: Currently not possible to implement. Think it would require new functionality (to insert a time lag) in NetSim
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 060 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0009
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_VerifyPosInfos
+
+END_TESTCASE LBS-X3P-Cancel-0009
+
+
+START_TESTCASE LBS-X3P-Cancel-0010
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0010
+//!@SYMTestCaseDesc Request X3P, then cancel after network has provided MoLrResult
+//!
+//!@SYMTestActions 1. Request current position be sent to a third party � RlbsTransmitPosition::TransmitPosition()
+//! 2. Wait for NetSim's notification that MOLR result has been sent to LBS
+//! 3. RLbsTransmitPosition::CancelTransmitPosition()
+//!
+//!@SYMTestExpectedResults No panic. X3P request completes with KErrNone or KErrCancel in CActive::Cancel()
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 1
+//!@SYMTestStatus Not Implemented
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 060 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0011
+
+END_TESTCASE LBS-X3P-Cancel-0010
+
+//This test added at end because it caused the next test fail.
+//Cancelling at More assistance data callback causes Network Gateway to ask for assistance data which affects next test
+
+START_TESTCASE LBS-X3P-Cancel-0011
+
+//!@SYMTestCaseID LBS-X3P-Cancel-0011
+//!@SYMTestCaseDesc Cancel X3P when we get NotifyMeasurementReportRequestMoreAssitanceData callback from NetSim
+//!
+//!@SYMTestActions 1. Set modDataIn.iAssDataTestMode = TModuleDataIn::EModuleTestModeAssDataOn_SomeDataNotAvailable so that
+//! Lbs system will ask for more assistance data to get position
+//! 2. Call TransmitPostion
+//! 3. Wait for NotifyMeasurementReportRequestMoreAssitanceData callback from NetSim
+//! 4. Call CancelTransmitPosition() to cancel X3P
+//!
+//!@SYMTestExpectedResults No panic. X3P request completes with KErrNone or KErrCancel in CActive::Cancel()
+//!
+//!@SYMPREQ PREQ 163
+//!@SYMREQ REQ 163.05
+//!
+//!@SYMTestType CIT
+//!@SYMTestPriority 1
+//!@SYMTestStatus Not Implemented
+
+
+RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_InstallScheduler
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_CreateVerifyPosInfos
+RUN_TEST_STEP 120 LbsX3PTestServer LbsX3PStep_Cancel c:\testdata\configs\lbsx3pcancel.ini LBS-X3P-Cancel-0010
+//RUN_TEST_STEP 010 LbsX3PTestServer LbsStep_VerifyPosInfos
+
+END_TESTCASE LBS-X3P-Cancel-0011
+
+
+PRINT Stop LBS
+RUN_TEST_STEP 020 LbsX3PTestServer LbsStep_StopLbs
+
+// Re-select the real A-GPS integration module.
+RUN_UTILS DeleteFile c:\private\10282253\lbs\locmods\agpsintegmodule.ini
+
+// Delete network registration status text file
+RUN_UTILS DeleteFile c:\config.txt