DEADHEAD: Fixes for bug 2680 seem to be obsolete
- no remaining references to the empty bld.inf files
- networkprotocolmodules/suplprotocolmodule/sfgroup/bld.inf has been deleted
// Copyright (c) 2006-2009 Nokia Corporation and/or its subsidiary(-ies).// All rights reserved.// This component and the accompanying materials are made available// under the terms of "Eclipse Public License v1.0"// which accompanies this distribution, and is available// at the URL "http://www.eclipse.org/legal/epl-v10.html".//// Initial Contributors:// Nokia Corporation - initial contribution.//// Contributors://// Description://LOAD_SUITE LbsClockTestServer -SharedDataPRINT Run LbsClockTestServerPRINT//Before we start LBS, select the test A-GPS integration module and network reg status txt file to use.PREFIX RUN_UTILS MkDir c:\private\10282253\ MkDir c:\private\10282253\lbs\ MkDir c:\private\10282253\lbs\locmods\ CopyFile c:\testdata\configs\xtestmodule.ini c:\private\10282253\lbs\locmods\agpsintegmodule.ini CopyFile c:\testdata\configs\lbstestconfig.txt c:\config.txt // Re-select the profile ini DeleteFile c:\private\10282253\lbs\lbsprofile.iniREMOVE_PREFIX// Selecting the default admin values will ensure the AGPS module requests assistance data.RUN_TEST_STEP 010 LbsClockTestServer LbsStep_ResetDefaultAdminRUN_TEST_STEP 030 LbsClockTestServer LbsStep_StartLbsRUN_TEST_STEP 010 LbsClockTestServer LbsStep_SetAutonomousModeSTART_TESTCASE LBS-Clock-0018//!@SYMTestCaseID LBS-Clock-0018//!@SYMTestCaseDesc Automatic clock adjust with the Auto Clock API switched on.//!//!@SYMTestActions 1. Switch on the Auto Clock API from the admin KSettingClockAdjust setting.//! 2. Request and process a position update.//!//!@SYMTestExpectedResults Verify the time is set correctly in step 3, the following approach is//! taken to verify time is updated correctly://! a. Record current time.//! b. Put clock forward by 2 hours.//! c. Sync the clock back to the actual time by carrying out a position update which//! in turn will re-adjust the clock via the location manager and its integration module.//! During the sync keep updating the record of current time, by an fixed interval, to allow later verification in step d.//! d. Ensure the time before and after adjust is roughly equal by 5 seconds.//! e. Repeat steps a - d and ensure time in d are equal by 2 seconds. //!//!@SYMPREQ PREQ 1616//!@SYMREQ REQ 1616.04//!@SYMREQ REQ 1616.06//!@SYMREQ REQ 1616.07//!@SYMREQ REQ 1616.10//!@SYMREQ REQ 1616.11//!//!@SYMTestType CIT//!@SYMTestPriority 1//!@SYMTestStatus Implemented.RUN_TEST_STEP 010 LbsClockTestServer LbsStep_InstallSchedulerRUN_TEST_STEP 020 LbsClockTestServer LbsStep_SetUpPsy c:\testdata\configs\lbsclock.ini LBS-ClockRUN_TEST_STEP 010 LbsClockTestServer LbsStep_CreateVerifyPosInfos c:\testdata\configs\lbsclock.ini LBS-Clock-0020RUN_TEST_STEP 020 LbsClockTestServer LbsClockStep_Main c:\testdata\configs\lbsclock.ini LBS-Clock-0020RUN_TEST_STEP 010 LbsClockTestServer LbsStep_VerifyLogInfoEND_TESTCASE LBS-Clock-0018START_TESTCASE LBS-Clock-0019//!@SYMTestCaseID LBS-Clock-0019//!@SYMTestCaseDesc Automatic clock adjust with the Auto Clock API switched on (adjust clock back).//!//!@SYMTestActions 1. Switch on the Auto Clock API from the admin KSettingClockAdjust setting.//! 2. Request and process a position update.//!//!@SYMTestExpectedResults Verify the time is set correctly in step 3, the following approach is//! taken to verify time is updated correctly://! a. Record current time.//! b. Put clock back by 2 hours.//! c. Sync the clock back to the actual time by carrying out a position update which//! in turn will re-adjust the clock via the location manager and its integration module.//! During the sync keep updating the record of current time, by an fixed interval, to allow later verification in step d.//! d. Ensure the time before and after adjust is roughly equal by 5 seconds.//! e. Repeat steps a - d and ensure time in d are equal by 2 seconds. //!//!@SYMPREQ PREQ 1616//!@SYMREQ REQ 1616.04//!@SYMREQ REQ 1616.06//!@SYMREQ REQ 1616.07//!@SYMREQ REQ 1616.11//!//!@SYMTestType CIT//!@SYMTestPriority 1//!@SYMTestStatus Implemented.RUN_TEST_STEP 010 LbsClockTestServer LbsStep_InstallSchedulerRUN_TEST_STEP 020 LbsClockTestServer LbsStep_SetUpPsy c:\testdata\configs\lbsclock.ini LBS-ClockRUN_TEST_STEP 010 LbsClockTestServer LbsStep_CreateVerifyPosInfos c:\testdata\configs\lbsclock.ini LBS-Clock-0021RUN_TEST_STEP 020 LbsClockTestServer LbsClockStep_Main c:\testdata\configs\lbsclock.ini LBS-Clock-0021RUN_TEST_STEP 010 LbsClockTestServer LbsStep_VerifyLogInfoEND_TESTCASE LBS-Clock-0019PRINT Stop LBSRUN_TEST_STEP 020 LbsClockTestServer LbsStep_StopLbs// Re-select the real A-GPS integration module.RUN_UTILS DeleteFile c:\private\10282253\lbs\locmods\agpsintegmodule.ini// Delete network registration status text fileRUN_UTILS DeleteFile c:\config.txt