lowlevellibsandfws/pluginfw/TestExecute/EComSWITests/scripts/TE_EComSWITestARM.script
Merge.
// Copyright (c) 2006-2009 Nokia Corporation and/or its subsidiary(-ies).
// All rights reserved.
// This component and the accompanying materials are made available
// under the terms of "Eclipse Public License v1.0"
// which accompanies this distribution, and is available
// at the URL "http://www.eclipse.org/legal/epl-v10.html".
//
// Initial Contributors:
// Nokia Corporation - initial contribution.
//
// Contributors:
//
// Description:
// @file
//
//
PRINT Run ECom SWI Install-Plugin Te_EComSWISuite Suite Tests
LOAD_SUITE TE_EComSWITestSuite
LOAD_SUITE TEFPlatSec
DELAY 3000
START_TESTCASE SYSLIB-ECOM-CIT-1889
//!@file
//!@SYMTestCaseID SYSLIB-ECOM-CIT-1889
//!@SYMTestCaseDesc Verify that an ECom Plugin can be Installed, Queried and Used
//! When it is Installed using Software Installer (SWI)
//!@SYMTestPriority High
//!@SYMTestActions (1) An ECom plugin which as packaged up into a .SIS is Installed Using SWI.
//! (2) The installed is queried for details of the plugins Implementation.
//! (3) The test tries to Call ReturnInt(),a method implemented by the ECom plugin
//! (4) The ECom plugin is uninstallesd suing SWI
//!
//!@SYMTestExpectedResults (1) The plugin is installed.
//! (2) The information provided by ListImplementationL macthes the expected data.
//! (3) ReturnInt() returns 123456789
//! (4) ECom unregisters plugin
RUN_TEST_STEP 100 TE_EComSWITestSuite InstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini Install_ARMSISP1
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckListImplUidStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CHECK_P1
DELAY 500
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckCreateImpl_ImpId_DtorId_Step Z:\TEF_EComSWI\ECom-SWI-UsePlugin.ini UsePlugin1
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite UninstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini UnInstallARMP1
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckListImplUidStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CHECK_P1_UNINSTALL
END_TESTCASE SYSLIB-ECOM-CIT-1889
START_TESTCASE SYSLIB-ECOM-CIT-1890
//!@file
//!@SYMTestCaseID SYSLIB-ECOM-CIT-1890
//!@SYMTestCaseDesc Verify that an ECom plugin that exists in the ROM (Z:) can be upgraded and downgraded
//! by a plugin installed and unistalled on the RAM (C:\) using SWI
//!
//!@SYMTestPriority High
//!@SYMTestActions
//! (1) ListImplmentaion is called on plugin v1.
//! (2) CreatListImplmentaionL is called on Plugin v1 method ReturnInt().
//! (3) ECom Plugin is upgraded to Version 2
//! (4) ListImplmentaion is called on plugin v2.
//! (5) ReturnInt(), a method provided by the plugin is called on Plugin v2.
//! (6) Plugin V2 is Uninstalled
//! (7) ListImplmentaion is called on plugin v1.
//!
//!@SYMTestExpectedResults (1) Plugin v1 exists on Z:\ drive and the specifed plugin attributes are returned.
//! (2) Int value is returned from ReturnInt(), Plugin v1.
//! (3) Ecom server now deregisteres v1 and registers v2.
//! (4) Plugin v2 exists on C:\ drive and the specifed plugin attributes are returned.
//! (5) Int value is returned from ReturnInt(), Plugin v2.
//! (6) Ecom server now deregisteres v2 and registers v1. Also no plugin v2 files exist.
//! (7) Plugin attribute information for v1 is returned.
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckListImplUidStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CHECK_P3
DELAY 500
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckCreateImpl_ImpId_DtorId_Step Z:\TEF_EComSWI\ECom-SWI-UsePlugin.ini UsePlugin3
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite InstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini InstallUpgrade_ARMSISP3
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckListImplUidStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CHECK_P3_UPGRADE
DELAY 500
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckCreateImpl_ImpId_DtorId_Step Z:\TEF_EComSWI\ECom-SWI-UsePlugin.ini UsePlugin3Upgrade
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite UninstallStepPackageName Z:\TEF_EComSWI\ECom-SWI-Install.ini UnInstallUpgradeARMP3
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckListImplUidStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CHECK_P3
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckCreateImpl_ImpId_DtorId_Step Z:\TEF_EComSWI\ECom-SWI-UsePlugin.ini UsePlugin3
DELAY 500
END_TESTCASE SYSLIB-ECOM-CIT-1890
START_TESTCASE SYSLIB-ECOM-CIT-1891
//!@file
//!@SYMTestCaseID SYSLIB-ECOM-CIT-1891
//!@SYMTestCaseDesc Verify that and Invalid ECom Plugin whose rss file has an incorrect dll
//! UID can be installed using SWI, but does not wok.
//!@SYMTestPriority High
//!@SYMTestActions (1) ECom Plugin is Installed
//! (2) Plugin queried for available implementation
//! (3) Plugin is Uninstalled
//!
//!@SYMTestExpectedResults (1) The files are installed.
//! (2) Query returns no implementations are available.
//! (3) The files are removed
RUN_TEST_STEP 100 TE_EComSWITestSuite InstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini Install_ARMSISP2
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckListImplUidStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CHECK_P2
DELAY 500
RUN_TEST_STEP 100 TE_EComSWITestSuite UninstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini UnInstallARMP2
END_TESTCASE SYSLIB-ECOM-CIT-1891
START_TESTCASE SYSLIB-ECOM-CIT-1919
//!@file
//!@SYMTestCaseID SYSLIB-ECOM-CIT-1919
//!@SYMTestCaseDesc Verify that an ECom plugin once installed on C: can be upgraded and downgraded
//! by a plugin installed and unistalled from the MMC using SWI
//!
//!@SYMTestPriority High
//!@SYMTestActions (1) ECom Plugin Version 1 is Installed on C:\ using SWI.
//! (2) ListImplmentaion is called on plugin v1.
//! (3) ReturnInt(), a method provided by the plugin is called on Plugin v1.
//! (4) ECom Plugin is upgraded to Version 2 and is Installed on MMC card using SWI
//! (5) ListImplmentaion is called on plugin v2.
//! (6) ReturnInt(), a method provided by the plugin is called on Plugin v2.
//! (7) Plugin V2 is Uninstalled
//! (8) ListImplmentaion is called to verify that plugin has been downgraded to v1
//! (9) Plugin v1 is Uninstalled
//!
//!@SYMTestExpectedResults (1) Plugin v1 files exist on the C:\ drive.
//! (2) Plugin attribute information for v1 is returned.
//! (3) Int value is returned from ReturnInt(), Plugin v1.
//! (4) Ecom server now deregisteres v1 and registers v2. Also Plugin v2 files
//! exist on the MMC drive.
//! (5) Plugin attribute information for v1 is returned.
//! (6) Int value is returned from ReturnInt(), Plugin v2.
//! (7) Ecom server now deregisteres v2 and registers v1. Also no plugin v2 files exist.
//! (8) Plugin attribute information for v1 is returned.
//! (9) Plugin v1 is uninstalled and no plugin files exist.
RUN_TEST_STEP 100 TE_EComSWITestSuite InstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini Install_ARMSISP1
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckListImplUidStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CHECK_P1
DELAY 500
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckCreateImpl_ImpId_DtorId_Step Z:\TEF_EComSWI\ECom-SWI-UsePlugin.ini UsePlugin1
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite InstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini InstallUpgrade_ARMSISP1
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckListImplUidStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CHECK_UPGRADE_P1_ARM
DELAY 500
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckCreateImpl_ImpId_DtorId_Step Z:\TEF_EComSWI\ECom-SWI-UsePlugin.ini UsePlugin1Upgrade
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite UninstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini UnInstallUpgradeARMP1
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckListImplUidStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CHECK_UPGRADE_P1_UNINSTALL
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite UninstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini UnInstallARMP1
DELAY 3000
RUN_TEST_STEP 100 TE_EComSWITestSuite CheckListImplUidStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CHECK_P1_UNINSTALL
END_TESTCASE SYSLIB-ECOM-CIT-1919
START_TESTCASE SYSLIB-ECOM-CIT-4011 //CachedResolverUpgradeBySWI
//!@SYMTestCaseID SYSLIB-ECOM-CIT-4011
//!@SYMTestCaseDesc Verify custom resolver caching do not interfere with SWI upgrading the resolver DLL.
//!@SYMTestPriority High
//!@SYMTestActions (1) Install version 2 of cachedcustomresolver so that the resolver is in RW drive.
//! (2) Use the resolver to get it in cache.
//! (3) Install version 9 of the resolver DLL.
//! (4) Check ECom uses version 9 of the resolver.
//! (5) Uninstall cachedcustomresolver.
//! NB: SWI behave differently on hw and winscw. In hw SWI can delete a DLL
//! while ECOM has the DLL loaded.
//!
//!@SYMTestExpectedResults (1) Version 2 is installed successfully.
//! (2) ECom instantiates the correct version, i.e. 2.
//! (3) Version 9 is successfully installed.
//! (4) ECom instantiate the correct version.
//! (5) Uninstall is successful.
//!@SYMCR CR1182
// Need a tef server with no capabilities to avoid platsec errors in listing custom resolvers
RUN_TEST_STEP 100 TEFPlatSec SetCapabilities Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini MakeNoCapServer
DELAY 2000
LOAD_SUITE ecomswinocapserver
RUN_TEST_STEP 100 TE_EComSWITestSuite ResolverInstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini Install_CustomResolver2
RUN_TEST_STEP 100 ecomswinocapserver UseCustomResolverStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CheckVersion2
RUN_TEST_STEP 100 TE_EComSWITestSuite ResolverInstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini Install_CustomResolver9
RUN_TEST_STEP 100 ecomswinocapserver UseCustomResolverStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CheckVersion9
RUN_TEST_STEP 100 TE_EComSWITestSuite ResolverUninstallStep Z:\TEF_EComSWI\ECom-SWI-Install.ini UnInstallCustomResolver
RUN_TEST_STEP 100 ecomswinocapserver UseCustomResolverStep Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini CheckVersion1
DELAY 4000
RUN_TEST_STEP 100 TEFPlatSec Cleanup Z:\TEF_EComSWI\ECom-SWI-CheckPlugin.ini MakeNoCapServer
END_TESTCASE SYSLIB-ECOM-CIT-4011 //CachedResolverUpgradeBySWI