<h2>Troubleshooting</h2>
<p>The following table lists AnalyzeTool error messages:</p>
<table width="615" border="1" cellspacing="1" cellpadding="2">
<colgroup>
<col width="250*">
<col width="356*"></colgroup>
<tbody>
<tr>
<th>Message</th>
<th align="center">Description</th>
</tr>
<tr>
<td>No project selected. Please select project.</td>
<td>You tried to use Carbide.c++ Extension actions but you have not selected a project first. Select a project from the <b>Project Explorer</b> window, and run action again.</td>
</tr>
<tr>
<td>Could not find mmp file for current project.</td>
<td>AnalyzeTool Carbide.c++ Extension could not load the mmp file info. Ensure that project's <i>bld.inf</i> file contains mmp files.</td>
</tr>
<tr>
<td>TraceViewer connection reserved for another plug-in.</td>
<td>Another Carbide.c++ Extension uses TraceViewer. First close the other TraceViewer Carbide.c++ Extension connection, and then try again.</td>
</tr>
<tr>
<td>Invalid TraceViewer connection settings.</td>
<td>The TraceViewer has invalid connection settings and could not connect to target hardware. Check the TraceViewer options from <b>Window > Preferences... > Carbide Extensions > TraceViewer > Connection</b>.</td>
</tr>
<tr>
<td>General TraceViewer error.</td>
<td>The TraceViewer cannot connect to target hardware and the AnalyzeTool Carbide.c++ Extension could not resolve the problem. Check the TraceViewer options from <b>Window > Preferences... > Carbide Extensions > TraceViewer > Connection</b>.</td>
</tr>
<tr>
<td>Invalid name. Do you want to specify a valid name?</td>
<td>You have entered an invalid subtest name, for example the name is empty or starts with an illegal parameter.</td>
</tr>
<tr>
<td>No process started, could not start a subtest.</td>
<td>The trace is active but no processes started in the target hardware which are built with the external data gathering mode of AnalyzeTool.</td>
</tr>
<tr>
<td>The given subtest is already started for the active process.</td>
<td>You have already started the subtest with same name for selected process.
</td>
</tr>
<tr>
<td>Cannot find AnalyzeTool libraries from current SDK. Install libraries first.</td>
<td>This message is displayed in the <b>Console</b> view if AnalyzeTool is not included in SDK.</td>
</tr>
</tbody>
</table>
<p>The following table lists possible known problematic situations related to AnalyzeTool:</p>
<table width="615" border="1" cellspacing="1" cellpadding="2">
<colgroup>
<col width="250*">
<col width="356*"></colgroup>
<tbody>
<tr>
<th>Problem</th>
<th align="center">Possible cause</th>
</tr>
<tr>
<td>Compiling with AnalyzeTool gives an error related to header files.</td>
<td>Mixing header files from different AnalyzeTool versions might be the cause. From version 1.5.0 onwards, AnalyzeTool uses a different folder structure compared to previous versions. Therefore it is essential that you check that there are no header files in the folder <i>\epoc32\include\applications\analyzetool</i> or <i>\epoc32\include\analyzetool</i>.</td>
</tr>
<tr>
<td>Compiling with AnalyzeTool gives an error related to AnalyzeTool library files.</td>
<td>Build environment is missing AnalyzeTool files. Install the AnalyzeTool to build environment by unzipping environment changes from AnalyzeTool installation folder.</i>.</td>
</tr>
<tr>
<td>Software compiled with AnalyzeTool does not run.</td>
<td>Mixing header files from different AnalyzeTool versions might be the cause. From version 1.5.0 onwards, AnalyzeTool uses a different folder structure compared to previous versions. Therefore it is essential that you check that there are no header files in the folder <i>\epoc32\include\applications\analyzetool</i> or <i>\epoc32\include\analyzetool</i>.</td>
</tr>
<tr>
<td>Software compiled with AnalyzeTool does not run.</td>
<td>AnalyzeTool core components are missing from the target HW/emulator environment.</td>
</tr>
<tr>
<td>Software compiled with AnalyzeTool does not run.</td>
<td>The AnalyzeTool core components in the target HW/emulator environment are old (incompatible) versions.</td>
</tr>
</tbody>
</table>
<p>The following ones are Command line engine related errors. These errors are displayed in the Carbide.c++ <b>Console</b> view.</p>
<table>
<colgroup>
<col width="250*">
<col width="356*"></colgroup>
<tbody>
<tr>
<th>Error</th>
<th align="center">Possible cause</th>
</tr>
<tr>
<td>Mmp file: <mmp file name> is read only. Compile aborted.</td>
<td>The project's mmp file is read only. Remove the write protection from the mmp file.</td>
</tr>
<tr>
<td>AnalyzeTool build failed in module: <mmp file name>.</td>
<td>Project contains build errors. Details can be found from <b>Console</b> view.</td>
</tr>
<tr>
<td>Can not find AnalyzeTool libraries from current SDK</td>
<td>Your build environment is missing the necessary files for building with AnalyzeTool. These files can be found from the AnalyzeTool installation folder from files S60_environment_changes31.zip, S60_environment_changes32.zip or S60_environment_changes50.zip. Unzip one of these to the desired Symbian OS root directory. The zip-package itself includes the necessary subfolder structure.</td>
</tr>
<tr>
<td>AnalyzeTool : Errors :<br>
Missing symbol file: <symbol file name></td>
<td>You are using GCCE release build which does not produce needed symbol files. Symbol files are needed to pinpoint memory leaks. To correct this user needs to add "<i>-debug</i>" to project's build configuration arguments. To do this open project's <b>properties</b>, select <b>Carbide.c++ > Build Configurations > Arguments</b> while the GCCE release build configuration is selected and write the <i>-debug</i> to arguments field.</td>
</tr>
</tbody>