diff -r bb339882c6e9 -r 0367d2db2c06 sysperfana/analyzetoolext/com.nokia.s60tools.analyzetool.help/html/gettingstarted/prerequisites.htm --- a/sysperfana/analyzetoolext/com.nokia.s60tools.analyzetool.help/html/gettingstarted/prerequisites.htm Tue Aug 24 12:10:03 2010 +0300 +++ b/sysperfana/analyzetoolext/com.nokia.s60tools.analyzetool.help/html/gettingstarted/prerequisites.htm Tue Aug 24 12:16:27 2010 +0300 @@ -1,38 +1,74 @@ - - -
- -For fully functioning, AnalyzeTool requires the following components:
-Note! If you have taken AnalyzeTool into use through the Nokia internal SymSEE Installer, the required components have been automatically installed to your PC.
- -To run analysis in the target hardware, AnalyzeTool needs to be installed. You can either choose to install AnalyzeTool through an installation package, or add AnalyzeTool to a phone image. You can find the needed files from the c:\apps\atool directory, if you have acquired AnalyzeTool through the Nokia internal SymSEE environment. If you want to install AnalyzeTool from a SIS package, unzip the AnalyzeToolPhone.zip which contains the binaries of the release and debug versions for the supported platforms. In case of ROM image inclusion, AnalyzeTool.iby needs to be included. In case of 5.x release, it is automatically included.
- -S60 version 5.0, 5.0.1, and 5.1 platforms and MCL releases include AnalyzeTool so if you are using one of those you do not need to take any actions. If you are using a platform which does not include AnalyzeTool, you have to add some AnalyzeTool files to the platform to be able to build with AnalyzeTool. If you have installed AnalyzeTool through the Nokia internal SymSEE environment, these files can be found from c:\apps\atool. The file name is S60_environment_changes_xx.zip where xx specifies the S60 platform version number. To install these files, unzip the file to the directory which contains the epoc32 directory. The zip file includes the necessary directory structure.
-Note! Errors about missing AnalyzeTool files are displayed in the problems view if your build environment is missing any necessary AnalyzeTool files.
- -If you intend to use External data gathering mode, check that TraceViewer Carbide.c++ Extension is configured correctly. Check the TraceViewer settings from Window > Preferences > Carbide Extensions > TraceViewer > Connection. For more information, see the TraceViewer Help.
- -For fully functioning, AnalyzeTool requires the following components:
+Note! If you have taken AnalyzeTool into use through the Nokia +internal SymSEE Installer, the required components have been automatically +installed to your PC.
+ +To run analysis in the target hardware, AnalyzeTool needs to be installed. +You can either choose to install AnalyzeTool through an installation package, +or add AnalyzeTool to a phone image. You can find the needed files from the +c:\apps\atool directory, if you have acquired AnalyzeTool through the +Nokia internal SymSEE environment. If you want to install AnalyzeTool from a +SIS package, unzip the AnalyzeToolPhone.zip which contains the binaries +of the release and debug versions for the supported platforms. In case of ROM +image inclusion, AnalyzeTool.iby needs to be included. In case of 5.x +release, it is automatically included.
+ +S60 version 5.0, 5.0.1, and 5.1 platforms and MCL releases include +AnalyzeTool so if you are using one of those you do not need to take any +actions. If you are using a platform which does not include AnalyzeTool, you +have to add some AnalyzeTool files to the platform to be able to build with +AnalyzeTool. If you have installed AnalyzeTool through the Nokia internal +SymSEE environment, these files can be found from c:\apps\atool. The +file name is S60_environment_changes_xx.zip where xx specifies +the S60 platform version number. To install these files, unzip the file to the +directory which contains the epoc32 directory. The zip file includes the +necessary directory structure.
+ +Note! Errors about missing AnalyzeTool files are displayed in the +problems view if your build environment is missing any necessary AnalyzeTool +files.
+ +If you intend to use output +to trace mode, check that TraceViewer Carbide.c++ Extension is configured +correctly. Check the TraceViewer settings from Window > Preferences > +Carbide Extensions > TraceViewer > Connection. For more information, +see the TraceViewer +Help.
+ +