testexecmgmt/ucc/Source/Uccs.v2/SCRIPT_Commands.txt
changeset 0 3da2a79470a7
equal deleted inserted replaced
-1:000000000000 0:3da2a79470a7
       
     1 
       
     2  --**-- Quick reference guide for UCCS Commands (more for programmers) --**--
       
     3 
       
     4 
       
     5 (2) UC_QUIT
       
     6 
       
     7 Stops the script thread. It sets a flag which prevents the remote control from 
       
     8 waiting on the rendezvous semaphore again (since it will block forever) and
       
     9 signals the rendezvous semaphore to release it if that's where it is now. This
       
    10 does not stop the use-case -- it will keep running until the device side runs
       
    11 end use case. 
       
    12 
       
    13 
       
    14 (3) UC_RUNCMD
       
    15 
       
    16 Runs the command. Does lots of stuff.
       
    17 
       
    18 
       
    19 (4) UC_ASSIGN
       
    20 
       
    21 Adds the specified elements to the environment object. This is then used by the
       
    22 parser in future commands.
       
    23 
       
    24 
       
    25 (5) UC_WAITFOR
       
    26 
       
    27 Waits for fields of the last reply to be at a certain value. It checks the value
       
    28 of the fields, and if they are not equal then it goes back to the last runcmd
       
    29 and runs all subsequent commands.
       
    30 
       
    31 FIXME: need to check what happens if there haven't been any runcmd's yet -- both
       
    32 in the case that this is the first command, and when this is not the first but
       
    33 the previous are all non-runcmd
       
    34 
       
    35 
       
    36 (6) UC_WAITFORSIGNAL
       
    37 
       
    38 Waits for a signal from the device
       
    39 
       
    40 
       
    41 (7) UC_RENDEZVOUS
       
    42 
       
    43 Rendezvous with the device
       
    44 
       
    45 
       
    46 (8) UC_REQUIRE
       
    47 
       
    48 Require a field to be a particular value. If the field is not correct then this is equivalent
       
    49 to a quit command.
       
    50 
       
    51 
       
    52 (9)	UC_REQUIRENOT
       
    53 
       
    54 Same as above however the logical not
       
    55 
       
    56 
       
    57 (10) UC_CHECK
       
    58 
       
    59 Checks that a field is a particular value. It differs from require in that if the condition
       
    60 is not met, the script continues to run, however, a warning is output.
       
    61 
       
    62 
       
    63 (11) UC_CHECKNOT
       
    64 
       
    65 Logical not of the above operation.
       
    66 
       
    67 
       
    68 (12) UC_PRINTENVIRONMENT
       
    69 
       
    70 Prints out all the environment variables.
       
    71 
       
    72 
       
    73 (13) UC_WAITFORNOT
       
    74 
       
    75 Same as waitfor but not.
       
    76 
       