 <concept id="GUID-85D9878E-4FEF-5E45-9F87-53634CD171E0" xml:lang="en"><title>Integrating
 a System Server with UPS</title><prolog><metadata><keywords/></metadata></prolog><conbody>
-<section><title>Introduction</title> <p>User Prompt Service (UPS) functionality
+<section id="GUID-78B46051-E035-4798-9A4D-B274D4783164"><title>Introduction</title> <p>User Prompt Service (UPS) functionality
 is provided by the server process <filepath>upsserver.exe</filepath>. The
 process starts on demand when system servers make calls to the UPS client
 library. Only applications with a capability of <codeph>ProtServ</codeph> or
@@ -22,11 +22,11 @@
 a system server that invokes the UPS, if a compatible dialog creator is available
 and the policies are delivered in an appropriately signed SIS file. They can
 also write a policy evaluator, but a default policy evaluator is provided
-by Symbian platform. </p> <p>If the device creators do not specify any policy
-file, the UPS uses the platform security check results to decide whether to
-access requested services. Thus not supplying policy files effectively turns
-UPS off. </p> </section>
-<section><title>Required background</title><p id="GUID-9C6EBADD-175A-5122-90C4-CED8A9855BAB"><b>Configuring
+by the Symbian platform. </p> <p>If the device creators do not
+specify any policy file, the UPS uses the platform security check results
+to decide whether to access requested services. Thus not supplying policy
+files effectively turns UPS off. </p> </section>
+<section id="GUID-718CF580-05FE-4F75-A7D8-4487C35675B6"><title>Required background</title><p id="GUID-9C6EBADD-175A-5122-90C4-CED8A9855BAB"><b>Configuring
 the system server</b> </p> <p>For each system server that accesses the UPS,
 you need to do the following: </p> <ol id="GUID-D14BDAE1-BD62-530E-B3C4-2FA380BDBDC5">
 <li id="GUID-090CE65B-44BF-54CF-8961-69059655C5F5"><p>Create one <codeph>RUpsSession</codeph> per
@@ -60,7 +60,7 @@
 check fails these checks may have to be modified. </p> </li>
 </ul><p> <b>Note</b>: For an example of how to include the above, see the
 example code later in this document. </p></section>
-<section><title>Integration of UPS</title> <p>If the system server uses the <codeph>CPolicyServer</codeph> framework,
+<section id="GUID-3C0A43C1-1CEF-4C0F-83A6-64B3EF73E955"><title>Integration of UPS</title> <p>If the system server uses the <codeph>CPolicyServer</codeph> framework,
 there are three candidates for the main integration point. </p> <table id="GUID-BBE389D8-77A0-52BA-910D-368BAC25DCC3">
 <tgroup cols="2"><colspec colname="col0"/><colspec colname="col1"/>
 <tbody>