--- /dev/null Thu Jan 01 00:00:00 1970 +0000
+++ b/omap3530/beagle_drivers/wb/api/include/cyaserr.h Wed Mar 03 13:10:32 2010 +0000
@@ -0,0 +1,1052 @@
+/* Cypress West Bridge API header file (cyaserr.h)
+ ## ===========================
+ ##
+ ## Copyright Cypress Semiconductor Corporation, 2006-2009,
+ ## All Rights Reserved
+ ## UNPUBLISHED, LICENSED SOFTWARE.
+ ##
+ ## CONFIDENTIAL AND PROPRIETARY INFORMATION
+ ## WHICH IS THE PROPERTY OF CYPRESS.
+ ##
+ ## Use of this file is governed
+ ## by the license agreement included in the file
+ ##
+ ## <install>/license/license.txt
+ ##
+ ## where <install> is the Cypress software
+ ## installation root directory path.
+ ##
+ ## ===========================
+*/
+
+#ifndef _INCLUDED_CYASERR_H_
+#define _INCLUDED_CYASERR_H_
+
+/*@@West Bridge Errors
+ Summary
+ This section lists the error codes for West Bridge.
+
+*/
+
+/* Summary
+ The function completed sucessfully
+*/
+#define CY_AS_ERROR_SUCCESS (0)
+
+/* Summary
+ A function trying to acquire a resource was unable to do so.
+
+ Description
+ This code indicates that a resource that the API was trying to claim
+ could not be claimed.
+
+ See Also
+ * CyAsMiscAcquireResource
+ * CyAsStorageClaim
+*/
+#define CY_AS_ERROR_NOT_ACQUIRED (1)
+
+/* Summary
+ A function trying to acquire a resource was unable to do so.
+
+ Description
+ The West Bridge API provides the capability to assign the storage media to
+ either the West Bridge device or the USB port. This error indicates the
+ P port was trying to release a storage media and was not able to do
+ so. This generally means it was not owned by the P port processor.
+
+ See Also
+ * CyAsStorageRelease
+*/
+#define CY_AS_ERROR_NOT_RELEASED (2)
+
+/* Summary
+ The West Bridge firmware is not loaded.
+
+ Description
+ Most of the API functions that are part of the West Bridge API rely on firmware
+ running on the West Bridge device. This error code is returned when one of
+ these functions is called and the firmware has not yet been loaded.
+
+ See Also
+ * CyAsMiscGetFirmwareVersion
+ * CyAsMiscReset
+ * CyAsMiscAcquireResource
+ * CyAsMiscReleaseResource
+ * CyAsMiscSetTraceLevel
+ * CyAsStorageStart
+ * CyAsStorageStop
+ * CyAsStorageRegisterCallback
+ * CyAsStorageClaim
+ * CyAsStorageRelease
+ * CyAsStorageQueryMedia
+ * CyAsStorageQueryDevice
+ * CyAsStorageQueryUnit
+ * CyAsStorageRead
+ * CyAsStorageWrite
+ * CyAsStorageReadAsync
+ * CyAsStorageWriteAsync
+*/
+#define CY_AS_ERROR_NO_FIRMWARE (3)
+
+/* Summary
+ A timeout occurred waiting on a response from the West Bridge device
+
+ Description
+ When requests are made of the West Bridge device, a response is expected
+ within a given timeframe. If a response is not recevied within the
+ given timeframe, a timeout error occurs.
+*/
+#define CY_AS_ERROR_TIMEOUT (4)
+
+/* Summary
+ A request to download firmware was made while not in the CONFIG mode
+
+ Description
+ Firmware is downloaded via the CyAsMiscDownloadFirmware() function. This
+ function can only be called while in the CONFIG mode. This error indicates
+ that the CyAsMiscDownloadFirmware() call was made while not in the CONFIG
+ mode.
+
+ See Also
+ * CyAsMiscDownloadFirmware
+*/
+#define CY_AS_ERROR_NOT_IN_CONFIG_MODE (5)
+
+/* Summary
+ This error is returned if the firmware size specified is too invalid.
+
+ Description
+ If the size of the firmware to be downloaded into West Bridge is invalid, this
+ error is issued. Invalid firmware sizes are those greater than 24K or a
+ size of zero.
+
+ See Also
+ * CyAsMiscDownloadFirmare
+*/
+#define CY_AS_ERROR_INVALID_SIZE (6)
+
+/* Summary
+ This error is returned if a request is made to acquire a resource that has
+ already been acquired.
+
+ Description
+ This error is returned if a request is made to acquire a resource that has
+ already been acquired.
+
+ See Also
+ * CyAsMiscAcquireResource
+ * CyAsMiscReleaseResource
+*/
+#define CY_AS_ERROR_RESOURCE_ALREADY_OWNED (7)
+
+/* Summary
+ This error is returned if a request is made to release a resource that has
+ not previously been acquired.
+
+ Description
+ This error is returned if a request is made to release a resource that has
+ not previously been acquired.
+
+ See Also
+ * CyAsMiscAcquireResource
+ * CyAsMiscReleaseResource
+*/
+#define CY_AS_ERROR_RESOURCE_NOT_OWNED (8)
+
+/* Summary
+ This error is returned when a request is made for a media that does not exist
+
+ Description
+ This error is returned when a request is made that references a storage media that
+ does not exist. This error is returned when the storage media is not present in
+ the current system, or if the media value given is not valid.
+
+ See Also
+ * CyAsMiscSetTraceLevel
+ * CyAsStorageClaim
+ * CyAsStorageRelease
+ * CyAsStorageRead
+ * CyAsStorageWrite
+ * CyAsStorageReadAsync
+ * CyAsStorageWriteAsync
+*/
+#define CY_AS_ERROR_NO_SUCH_MEDIA (9)
+
+/* Summary
+ This error is returned when a request is made for a device that does not exist
+
+ Description
+ This error is returned when a request is made that references a storage device
+ that does not exist. This error is returned when the device index is not present
+ in the current system, or if the device index exceeds 15.
+
+ See Also
+ * CyAsMiscSetTraceLevel
+ * CyAsStorageQueryDevice
+ * CyAsStorageRead
+ * CyAsStorageWrite
+ * CyAsStorageReadAsync
+ * CyAsStorageWriteAsync
+*/
+#define CY_AS_ERROR_NO_SUCH_DEVICE (10)
+
+/* Summary
+ This error is returned when a request is made for a unit that does not exist
+
+ Description
+ This error is returned when a request is made that references a storage unit
+ that does not exist. This error is returned when the unit index is not present
+ in the current system, or if the unit index exceeds 255.
+
+ See Also
+ * CyAsMiscSetTraceLevel
+ * CyAsStorageQueryDevice
+ * CyAsStorageQueryUnit
+ * CyAsStorageRead
+ * CyAsStorageWrite
+ * CyAsStorageReadAsync
+ * CyAsStorageWriteAsync
+*/
+#define CY_AS_ERROR_NO_SUCH_UNIT (11)
+
+/* Summary
+ This error is returned when a request is made for a block that does not exist
+
+ Description
+ This error is returned when a request is made that references a storage block
+ that does not exist. This error is returned when the block address reference
+ an address beyond the end of the unit selected.
+
+ See Also
+ * CyAsStorageRead
+ * CyAsStorageWrite
+ * CyAsStorageReadAsync
+ * CyAsStorageWriteAsync
+*/
+#define CY_AS_ERROR_INVALID_BLOCK (12)
+
+/* Summary
+ This error is returned when an invalid trace level is set.
+
+ Description
+ This error is returned when the trace level request is greater
+ than three.
+
+ See Also
+ * CyAsMiscSetTraceLevel
+*/
+#define CY_AS_ERROR_INVALID_TRACE_LEVEL (13)
+
+/* Summary
+ This error is returned when West Bridge is already in the standby state
+ and an attempt is made to put West Bridge into this state again.
+
+ Description
+ This error is returned when West Bridge is already in the standby state
+ and an attempt is made to put West Bridge into this state again.
+
+ See Also
+ * CyAsMiscEnterStandby
+*/
+#define CY_AS_ERROR_ALREADY_STANDBY (14)
+
+/* Summary
+ This error is returned when the API needs to set a pin on the
+ West Bridge device, but this is not supported by the underlying HAL
+ layer.
+
+ Description
+ This error is returned when the API needs to set a pin on the
+ West Bridge device, but this is not supported by the underlying HAL
+ layer.
+
+ See Also
+ * CyAsMiscEnterStandby
+ * CyAsMiscLeaveStandby
+*/
+#define CY_AS_ERROR_SETTING_WAKEUP_PIN (15)
+
+/* Summary
+ This error is returned when a module is being started that has
+ already been started.
+
+ Description
+ This error is returned when a module is being started and that module
+ has already been started. This error does not occur with the CyAsStorageStart()
+ or CyAsUsbStart() functions as the storage and USB modules are reference counted.
+
+ Note
+ At the current time, this error is returned by module internal to the API but
+ not returned by any of the API functions.
+*/
+#define CY_AS_ERROR_ALREADY_RUNNING (16)
+
+/* Summary
+ This error is returned when a module is being stopped that has
+ already been stopped.
+
+ Description
+ This error is returned when a module is being stopped and that module
+ has already been stopped. This error does not occur with the CyAsStorageStop()
+ or CyAsUsbStop() functions as the storage and USB modules are reference counted.
+
+ Note
+ At the current time, this error is returned by module internal to the API but
+ not returned by any of the API functions.
+*/
+
+#define CY_AS_ERROR_NOT_RUNNING (17)
+
+/* Summary
+ This error is returned when the caller tries to claim a media that has already been
+ claimed.
+
+ Description
+ This error is returned when the caller tries to claim a media that has already been
+ claimed.
+
+ See Also
+ * CyAsStorageClaim
+*/
+#define CY_AS_ERROR_MEDIA_ALREADY_CLAIMED (18)
+
+/* Summary
+ This error is returned when the caller tries to release a media that has already been
+ released.
+
+ Description
+ This error is returned when the caller tries to release a media that has already been
+ released.
+
+ See Also
+ * CyAsStorageRelease
+*/
+#define CY_AS_ERROR_MEDIA_NOT_CLAIMED (19)
+
+/* Summary
+ This error is returned when canceling trying to cancel an asynchronous operation when
+ an async operation is not pending.
+
+ Description
+ This error is returned when a call is made to a function to cancel an asynchronous operation
+ and there is no asynchronous operation pending.
+
+ See Also
+ * CyAsStorageCancelAsync
+ * CyAsUsbCancelAsync
+*/
+#define CY_AS_ERROR_NO_OPERATION_PENDING (20)
+
+/* Summary
+ This error is returned when an invalid endpoint number is provided to an API call.
+
+ Description
+ This error is returned when an invalid endpoint number is specified in an API call. The
+ endpoint number may be invalid because it is greater than 15, or because it was a reference
+ to an endpoint that is invalid for West Bridge (2, 4, 6, or 8).
+
+ See Also
+ * CyAsUsbSetEndPointConfig
+ * CyAsUsbGetEndPointConfig
+ * CyAsUsbReadData
+ * CyAsUsbWriteData
+ * CyAsUsbReadDataAsync
+ * CyAsUsbWriteDataAsync
+ * CyAsUsbSetStall
+ * CyAsUsbGetStall
+*/
+#define CY_AS_ERROR_INVALID_ENDPOINT (21)
+
+/* Summary
+ This error is returned when an invalid descriptor type
+ is specified in an API call.
+
+ Description
+ This error is returned when an invalid descriptor type
+ is specified in an API call.
+
+ See Also
+ * CyAsUsbSetDescriptor
+ * CyAsUsbGetDescriptor
+*/
+#define CY_AS_ERROR_INVALID_DESCRIPTOR (22)
+
+/* Summary
+ This error is returned when an invalid descriptor index
+ is specified in an API call.
+
+ Description
+ This error is returned when an invalid descriptor index
+ is specified in an API call.
+
+ See Also
+ * CyAsUsbSetDescriptor
+ * CyAsUsbGetDescriptor
+*/
+#define CY_AS_ERROR_BAD_INDEX (23)
+
+/* Summary
+ This error is returned if trying to set a USB descriptor
+ when in the P port enumeration mode.
+
+ Description
+ This error is returned if trying to set a USB descriptor
+ when in the P port enumeration mode.
+
+ See Also
+ * CyAsUsbSetDescriptor
+ * CyAsUsbGetDescriptor
+*/
+#define CY_AS_ERROR_BAD_ENUMERATION_MODE (24)
+
+/* Summary
+ This error is returned when the endpoint configuration specified
+ is not valid.
+
+ Description
+ This error is returned when the endpoint configuration specified
+ is not valid.
+
+ See Also
+ * CyAsUsbSetDescriptor
+ * CyAsUsbGetDescriptor
+ * CyAsUsbCommitConfig
+*/
+#define CY_AS_ERROR_INVALID_CONFIGURATION (25)
+
+/* Summary
+ This error is returned when the API cannot verify it is connected
+ to an West Bridge device.
+
+ Description
+ When the API is initialized, the API tries to read the ID register from
+ the West Bridge device. The value from this ID register should match the
+ value expected before communications with West Bridge are established. This
+ error means that the contents of the ID register cannot be verified.
+
+ See Also
+ * CyAsMiscConfigureDevice
+*/
+#define CY_AS_ERROR_NO_ANTIOCH (26)
+
+/* Summary
+ This error is returned when an API function is called and CyAsMiscConfigureDevice
+ has not been called to configure West Bridge for the current environment.
+
+ Description
+ This error is returned when an API function is called and CyAsMiscConfigureDevice
+ has not been called to configure West Bridge for the current environment.
+
+ See Also
+ * Almost all API function
+*/
+#define CY_AS_ERROR_NOT_CONFIGURED (27)
+
+/* Summary
+ This error is returned when West Bridge cannot allocate memory required for
+ internal API operations.
+
+ Description
+ This error is returned when West Bridge cannot allocate memory required for
+ internal API operations.
+
+ See Also
+ * Almost all API functoins
+*/
+#define CY_AS_ERROR_OUT_OF_MEMORY (28)
+
+/* Summary
+ This error is returned when a module is being started that has
+ already been started.
+
+ Description
+ This error is returned when a module is being started and that module
+ has already been started. This error does not occur with the CyAsStorageStart()
+ or CyAsUsbStart() functions as the storage and USB modules are reference counted.
+
+ Note
+ At the current time, this error is returned by module internal to the API but
+ not returned by any of the API functions.
+*/
+#define CY_AS_ERROR_NESTED_SLEEP (29)
+
+/* Summary
+ This error is returned when an operation is attempted on an endpoint that has
+ been disabled.
+
+ Description
+ This error is returned when an operation is attempted on an endpoint that has
+ been disabled.
+
+ See Also
+ * CyAsUsbReadData
+ * CyAsUsbWriteData
+ * CyAsUsbReadDataAsync
+ * CyAsUsbWriteDataAsync
+*/
+#define CY_AS_ERROR_ENDPOINT_DISABLED (30)
+
+/* Summary
+ This error is returned when a call is made to an API function when the device is in
+ standby.
+
+ Description
+ When the West Bridge device is in standby, the only two API functions that can be called
+ are CyAsMiscInStandby() and CyAsMiscLeaveStandby(). Calling any other API function
+ will result in this error.
+
+ See Also
+*/
+#define CY_AS_ERROR_IN_STANDBY (31)
+
+/* Summary
+ This error is returned when an API call is made with an invalid handle value.
+
+ Description
+ This error is returned when an API call is made with an invalid handle value.
+
+ See Also
+*/
+#define CY_AS_ERROR_INVALID_HANDLE (32)
+
+/* Summary
+ This error is returned when an invalid response is returned from the West Bridge device.
+
+ Description
+ Many of the API calls result in requests made to the West Bridge device. This error occurs
+ when the response from West Bridge is invalid and generally indicates that the West Bridge device
+ should be reset.
+
+ See Also
+*/
+#define CY_AS_ERROR_INVALID_RESPONSE (33)
+
+/* Summary
+ This error is returned from the callback function for any asynchronous read or write
+ request that is canceled.
+
+ Description
+ When asynchronous requests are canceled, this error is passed to the callback function
+ associated with the request to indicate that the request has been canceled
+
+ See Also
+ * CyAsStorageReadAsync
+ * CyAsStorageWriteAsync
+ * CyAsUsbReadDataAsync
+ * CyAsUsbWriteDataAsync
+ * CyAsStorageCancelAsync
+ * CyAsUsbCancelAsync
+*/
+#define CY_AS_ERROR_CANCELED (34)
+
+/* Summary
+ This error is returned when the call to create sleep channel fails
+ in the HAL layer.
+
+ Description
+ This error is returned when the call to create sleep channel fails
+ in the HAL layer.
+
+ See Also
+ * CyAsMiscConfigureDevice
+*/
+#define CY_AS_ERROR_CREATE_SLEEP_CHANNEL_FAILED (35)
+
+/* Summary
+ This error is returned when the call to CyAsMiscLeaveStandby
+ is made and the device is not in standby.
+
+ Description
+ This error is returned when the call to CyAsMiscLeaveStandby
+ is made and the device is not in standby.
+
+ See Also
+*/
+#define CY_AS_ERROR_NOT_IN_STANDBY (36)
+
+/* Summary
+ This error is returned when the call to destroy sleep channel fails
+ in the HAL layer.
+
+ Description
+ This error is returned when the call to destroy sleep channel fails
+ in the HAL layer.
+
+ See Also
+ * CyAsMiscDestroyDevice
+*/
+#define CY_AS_ERROR_DESTROY_SLEEP_CHANNEL_FAILED (37)
+
+/* Summary
+ This error is returned when an invalid resource is specified to a call
+ to CyAsMiscAcquireResource() or CyAsMiscReleaseResource()
+
+ Description
+ This error is returned when an invalid resource is specified to a call
+ to CyAsMiscAcquireResource() or CyAsMiscReleaseResource()
+
+ See Also
+ * CyAsMiscAcquireResource
+ * CyAsMiscReleaseResource
+*/
+#define CY_AS_ERROR_INVALID_RESOURCE (38)
+
+/* Summary
+ This error occurs when an operation is requested on an endpoint that has
+ a currently pending async operation.
+
+ Description
+ There can only be a single asynchronous pending operation on a given endpoint and
+ while the operation is pending on other operation can occur on the endpoint. In
+ addition, the device cannot enter standby while any asynchronous operations are
+ pending.
+
+ See Also
+ * CyAsStorageReadAsync
+ * CyAsStorageWriteAsync
+ * CyAsUsbReadDataAsync
+ * CyAsUsbWriteDataAsync
+ * CyAsStorageRead
+ * CyAsStorageWrite
+ * CyAsUsbReadData
+ * CyAsUsbWriteData
+ * CyAsMiscEnterStandby
+*/
+#define CY_AS_ERROR_ASYNC_PENDING (39)
+
+/* Summary
+ This error is returned when a call to CyAsStorageCancelAsync() or
+ CyAsUsbCancelAsync() is made when no asynchronous request is pending.
+
+ Description
+ This error is returned when a call to CyAsStorageCancelAsync() or
+ CyAsUsbCancelAsync() is made when no asynchronous request is pending.
+
+ See Also
+ * CyAsStorageCancelAsync
+ * CyAsUsbCancelAsync
+*/
+#define CY_AS_ERROR_ASYNC_NOT_PENDING (40)
+
+/* Summary
+ This error is returned when a request is made to put the West Bridge device
+ into standby mode while the USB stack is still active.
+
+ Description
+ This error is returned when a request is made to put the West Bridge device
+ into standby mode while the USB stack is still active. You must call the
+ function CyAsUsbStop() in order to shut down the USB stack in order to go
+ into the standby mode.
+
+ See Also
+ * CyAsMiscEnterStandby
+*/
+#define CY_AS_ERROR_USB_RUNNING (41)
+
+/* Summary
+ A request for in the wrong direction was issued on an endpoint.
+
+ Description
+ This error is returned when a write is attempted on an OUT endpoint or
+ a read is attempted on an IN endpoint.
+
+ See Also
+ * CyAsUsbReadData
+ * CyAsUsbWriteData
+ * CyAsUsbReadDataAsync
+ * CyAsUsbWriteDataAsync
+*/
+#define CY_AS_ERROR_USB_BAD_DIRECTION (42)
+
+/* Summary
+ An invalid request was received
+
+ Description
+ This error is isused if an invalid request is issued.
+*/
+#define CY_AS_ERROR_INVALID_REQUEST (43)
+
+/* Summary
+ An ACK request was requested while no setup packet was pending.
+
+ Description
+ This error is issued if CyAsUsbAckSetupPacket() is called when no setup packet is
+ pending.
+*/
+#define CY_AS_ERROR_NO_SETUP_PACKET_PENDING (44)
+
+/* Summary
+ A call was made to a API function that cannot be called from a callback.
+
+ Description
+ Only asynchronous functions can be called from within West Bridge callbacks.
+ This error results when an invalid function is called from a callback.
+*/
+#define CY_AS_ERROR_INVALID_IN_CALLBACK (45)
+
+/* Summary
+ A call was made to CyAsUsbSetEndPointConfig() before CyAsUsbSetPhysicalConfiguration()
+ was called.
+
+ Description
+ When logical endpoints are configured, you must define the physical endpoint for the
+ logical endpoint being configured. Therefore CyAsUsbSetPhysicalConfiguration() must
+ be called to define the physical endpoints before calling CyAsUsbSetEndPointConfig().
+*/
+#define CY_AS_ERROR_ENDPOINT_CONFIG_NOT_SET (46)
+
+/* Summary
+ The physical endpoint referenced is not valid in the current physical configuration
+
+ Description
+ When logical endpoints are configured, you must define the physical endpoint for the
+ logical endpoint being configured. Given the current physical configuration, the
+ physical endpoint referenced is not valid.
+*/
+#define CY_AS_ERROR_INVALID_PHYSICAL_ENDPOINT (47)
+
+/* Summary
+ The data supplied to the CyAsMiscDownloadFirmware() call is not aligned on a
+ WORD (16 bit) boundary.
+
+ Description
+ Many systems have problems with the transfer of data a word at a time when the
+ data is not word aligned. For this reason, we require that the firmware image
+ be aligned on a word boundary and be an even number of bytes. This error is returned
+ if these conditions are not met.
+*/
+#define CY_AS_ERROR_ALIGNMENT_ERROR (48)
+
+/* Summary
+ A call was made to destroy the West Bridge device, but the USB stack or the storage
+ stack was will running.
+
+ Description
+ Before calling CyAsMiscDestroyDevice to destroy an West Bridge device created via a
+ call to CyAsMiscCreateDevice, the USB and STORAGE stacks much be stopped via calls
+ to CyAsUsbStop and CyAsStorageStop. This error indicates that one of these two
+ stacks have not been stopped.
+*/
+#define CY_AS_ERROR_STILL_RUNNING (49)
+
+/* Summary
+ A call was made to the API for a function that is not yet supported.
+
+ Description
+ There are calls that are not yet supported that may be called through the API. This
+ is done to maintain compatibility in the future with the API. This error is returned
+ if you are asking for a capability that does not yet exist.
+*/
+#define CY_AS_ERROR_NOT_YET_SUPPORTED (50)
+
+/* Summary
+ A NULL callback was provided where a non-NULL callback was required
+
+ Description
+ When async IO function are called, a callback is required to indicate that the
+ IO has completed. This callback must be non-NULL.
+*/
+#define CY_AS_ERROR_NULL_CALLBACK (51)
+
+/* Summary
+ This error is returned when a request is made to put the West Bridge device
+ into standby mode while the storage stack is still active.
+
+ Description
+ This error is returned when a request is made to put the West Bridge device
+ into standby mode while the storage stack is still active. You must call the
+ function CyAsStorageStop() in order to shut down the storage stack in order to go
+ into the standby mode.
+
+ See Also
+ * CyAsMiscEnterStandby
+*/
+#define CY_AS_ERROR_STORAGE_RUNNING (52)
+
+/* Summary
+ This error is returned when an operation is attempted that cannot be completed while
+ the USB stack is connected to a USB host.
+
+ Description
+ This error is returned when an operation is attempted that cannot be completed while
+ the USB stack is connected to a USB host. In order to sucessfully complete the
+ desired operation, CyAsUsbDisconnect() must be called to disconnect from the host.
+*/
+#define CY_AS_ERROR_USB_CONNECTED (53)
+
+/* Summary
+ This error is returned when a USB disconnect is attempted and the West Bridge device is
+ not connected.
+
+ Description
+ This error is returned when a USB disconnect is attempted and the West Bridge device is
+ not connected.
+*/
+#define CY_AS_ERROR_USB_NOT_CONNECTED (54)
+
+/* Summary
+ This error is returned when an P2S storage operation attempted and data could not be
+ read or written to the storage media.
+
+ Description
+ This error is returned when an P2S storage operation attempted and data could not be
+ read or written to the storage media. If this error is recevied then a retry can be
+ done.
+*/
+#define CY_AS_ERROR_MEDIA_ACCESS_FAILURE (55)
+
+/* Summary
+ This error is returned when an P2S storage operation attempted and the media is write
+ protected.
+
+ Description
+ This error is returned when an P2S storage operation attempted and the media is write
+ protected.
+*/
+#define CY_AS_ERROR_MEDIA_WRITE_PROTECTED (56)
+
+/* Summary
+ This error is returned when an attempt is made to cancel a request that has
+ already been sent to the West Bridge.
+
+ Description
+ It is not possible to cancel an asynchronous storage read/write operation after
+ the actual data transfer with the West Bridge has started. This error is returned
+ if CyAsStorageCancelAsync is called to cancel such a request.
+ */
+#define CY_AS_ERROR_OPERATION_IN_TRANSIT (57)
+
+/* Summary
+ This error is returned when an invalid parameter is passed to one of the APIs.
+
+ Description
+ Some of the West Bridge APIs are applicable to only specific media types, devices
+ etc. This error code is returned when a API is called with an invalid parameter
+ type.
+ */
+#define CY_AS_ERROR_INVALID_PARAMETER (58)
+
+/* Summary
+ This error is returned if an API is not supported in the current setup.
+
+ Description
+ Some of the West Bridge APIs work only with specific device types or firmware images.
+ This error is returned when such APIs are called when the current device or firmware
+ does not support the invoked API function.
+ */
+#define CY_AS_ERROR_NOT_SUPPORTED (59)
+
+/* Summary
+ This error is returned when a call is made to one of the Storage or
+ USB APIs while the device is in suspend mode.
+
+ Description
+ This error is returned when a call is made to one of the storage or
+ USB APIs while the device is in suspend mode.
+ */
+#define CY_AS_ERROR_IN_SUSPEND (60)
+
+/* Summary
+ This error is returned when the call to CyAsMiscLeaveSuspend
+ is made and the device is not in suspend mode.
+
+ Description
+ This error is returned when the call to CyAsMiscLeaveSuspend
+ is made and the device is not in suspend mode.
+ */
+#define CY_AS_ERROR_NOT_IN_SUSPEND (61)
+
+/* Summary
+ This error is returned when a command that is disabled by USB is called.
+
+ Description
+ The remote wakeup capability should be exercised only if enabled by the USB host.
+ This error is returned when the CyAsUsbSignalRemoteWakeup API is called when the
+ feature has not been enabled by the USB host.
+ */
+#define CY_AS_ERROR_FEATURE_NOT_ENABLED (62)
+
+/* Summary
+ This error is returned when an Async storage read or write is called before a
+ query device call is issued.
+
+ Description
+ In order for the SDK to properly set up a DMA the block size of a given media
+ needs to be known. This is done by making a call to CyAsStorageQueryDevice. This
+ call only needs to be made once per device. If this call is not issued before
+ an Async read or write is issued this error code is returned.
+ */
+#define CY_AS_ERROR_QUERY_DEVICE_NEEDED (63)
+
+/* Summary
+ This error is returned when a call is made to USB or STORAGE Start or Stop before
+ a prior Start or Stop has finished.
+
+ Description
+ The USB and STORAGE start and stop functions can only be called if a prior start
+ or stop function call has fully completed. This means when an async EX call is made
+ you must wait until the callback for that call has been completed before calling
+ start or stop again.
+ */
+#define CY_AS_ERROR_STARTSTOP_PENDING (64)
+
+/* Summary
+ This error is returned when a request is made for a bus that does not exist
+
+ Description
+ This error is returned when a request is made that references a bus number that
+ does not exist. This error is returned when the bus number is not present in
+ the current system, or if the bus number given is not valid.
+
+ See Also
+ * CyAsMiscSetTraceLevel
+ * CyAsStorageClaim
+ * CyAsStorageRelease
+ * CyAsStorageRead
+ * CyAsStorageWrite
+ * CyAsStorageReadAsync
+ * CyAsStorageWriteAsync
+*/
+#define CY_AS_ERROR_NO_SUCH_BUS (65)
+
+/* Summary
+ This error is returned when the bus corresponding to a media type cannot be resolved.
+
+ Description
+ In some S-Port configurations, the same media type may be supported on multiple
+ buses. In this case, it is not possible to resolve the target address based on the
+ media type. This error indicates that only bus-based addressing is supported
+ in a particular run-time configuration.
+
+ See Also
+ * CyAsMediaType
+ * CyAsBusNumber_t
+ */
+#define CY_AS_ERROR_ADDRESS_RESOLUTION_ERROR (66)
+
+/* Summary
+ This error is returned when an invalid command is passed to the CyAsStorageSDIOSync()
+ function.
+
+ Description
+ This error indiactes an unknown Command type was passed to the SDIO command handler
+ function.
+ */
+
+#define CY_AS_ERROR_INVALID_COMMAND (67)
+
+
+/* Summary
+ This error is returned when an invalid function /uninitialized function is passed to an SDIO
+ function.
+
+ Description
+ This error indiactes an unknown/uninitialized function number was passed to a SDIO
+ function.
+ */
+#define CY_AS_ERROR_INVALID_FUNCTION (68)
+
+/* Summary
+ This error is returned when an invalid block size is passed to CyAsSdioSetBlocksize().
+
+ Description
+ This error is returned when an invalid block size (greater than maximum block size supported)is
+ passed to CyAsSdioSetBlocksize().
+ */
+
+#define CY_AS_ERROR_INVALID_BLOCKSIZE (69)
+
+/* Summary
+ This error is returned when an tuple requested is not found.
+
+ Description
+ This error is returned when an tuple requested is not found.
+ */
+#define CY_AS_ERROR_TUPLE_NOT_FOUND (70)
+
+/* Summary
+ This error is returned when an extended IO operation to an SDIO function is
+ Aborted.
+ Description
+ This error is returned when an extended IO operation to an SDIO function is
+ Aborted. */
+#define CY_AS_ERROR_IO_ABORTED (71)
+
+/* Summary
+ This error is returned when an extended IO operation to an SDIO function is
+ Suspended.
+ Description
+ This error is returned when an extended IO operation to an SDIO function is
+ Suspended. */
+#define CY_AS_ERROR_IO_SUSPENDED (72)
+
+/* Summary
+ This error is returned when IO is attempted to a Suspended SDIO function.
+ Description
+ This error is returned when IO is attempted to a Suspended SDIO function. */
+#define CY_AS_ERROR_FUNCTION_SUSPENDED (73)
+
+/* Summary
+ This error is returned if an MTP function is called before MTPStart has completed.
+ Description
+ This error is returned if an MTP function is called before MTPStart has completed.
+*/
+#define CY_AS_ERROR_MTP_NOT_STARTED (74)
+
+/* Summary
+ This error is returned by API functions that are not valid in MTP mode (CyAsStorageClaim for example)
+ Description
+ This error is returned by API functions that are not valid in MTP mode (CyAsStorageClaim for example)
+*/
+#define CY_AS_ERROR_NOT_VALID_IN_MTP (75)
+
+/* Summary
+ This error is returned when an attempt is made to partition a storage device that is already
+ partitioned.
+
+ Description
+ This error is returned when an attempt is made to partition a storage device that is already
+ partitioned.
+*/
+#define CY_AS_ERROR_ALREADY_PARTITIONED (76)
+
+/* Summary
+ This error is returned when a call is made to CyAsUsbSelectMSPartitions after CyAsUsbSetEnumConfig
+ is called.
+
+ Description
+ This error is returned when a call is made to CyAsUsbSelectMSPartitions after CyAsUsbSetEnumConfig
+ is called.
+ */
+#define CY_AS_ERROR_INVALID_CALL_SEQUENCE (77)
+
+/* Summary
+ This error is returned when a StorageWrite opperation is attempted during an ongoing MTP transfer.
+ Description
+ This error is returned when a StorageWrite opperation is attempted during an ongoing MTP transfer.
+ A MTP transfer is initiated by a call to CyAsMTPInitSendObject or CyAsMTPInitGetObject and is not
+ finished until the CyAsMTPSendObjectComplete or CyAsMTPGetObjectComplete event is generated.
+*/
+#define CY_AS_ERROR_NOT_VALID_DURING_MTP (78)
+
+/* Summary
+ This error is returned when a StorageRead or StorageWrite is attempted while a UsbRead or UsbWrite on
+ a Turbo endpoint (2 or 6) is pending, or visa versa.
+ Description
+ When there is a pending usb read or write on a turbo endpoint (2 or 6) a storage read or write call
+ may not be performed. Similarly when there is a pending storage read or write a usb read or write may
+ not be performed on a turbo endpoint (2 or 6).
+*/
+#define CY_AS_ERROR_STORAGE_EP_TURBO_EP_CONFLICT (79)
+
+/* Summary
+ This error is returned when processor requests to reserve greater number of zones than available for
+ proc booting via lna firmware.
+
+ Description
+ Astoria does not allocate any nand zones for the processor in this case.
+*/
+#define CY_AS_ERROR_EXCEEDED_NUM_ZONES_AVAIL (80)
+
+#endif /* _INCLUDED_CYASERR_H_ */