Modify framebuffer and NGA framebuffer to read screen size from board model dtb file. Optimise memory usuage of frame buffer
Add example minigui application with hooks to profiler (which writes results to S:\). Modified NGA framebuffer to run its own dfc queue at high priority
<HTML
><HEAD
><TITLE
>SDL_CondWaitTimeout</TITLE
><META
NAME="GENERATOR"
CONTENT="Modular DocBook HTML Stylesheet Version 1.76b+
"><LINK
REL="HOME"
TITLE="SDL Library Documentation"
HREF="index.html"><LINK
REL="UP"
TITLE="Multi-threaded Programming"
HREF="thread.html"><LINK
REL="PREVIOUS"
TITLE="SDL_CondWait"
HREF="sdlcondwait.html"><LINK
REL="NEXT"
TITLE="Time"
HREF="time.html"></HEAD
><BODY
CLASS="REFENTRY"
BGCOLOR="#FFF8DC"
TEXT="#000000"
LINK="#0000ee"
VLINK="#551a8b"
ALINK="#ff0000"
><DIV
CLASS="NAVHEADER"
><TABLE
SUMMARY="Header navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TH
COLSPAN="3"
ALIGN="center"
>SDL Library Documentation</TH
></TR
><TR
><TD
WIDTH="10%"
ALIGN="left"
VALIGN="bottom"
><A
HREF="sdlcondwait.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="80%"
ALIGN="center"
VALIGN="bottom"
></TD
><TD
WIDTH="10%"
ALIGN="right"
VALIGN="bottom"
><A
HREF="time.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
></TABLE
><HR
ALIGN="LEFT"
WIDTH="100%"></DIV
><H1
><A
NAME="SDLCONDWAITTIMEOUT"
></A
>SDL_CondWaitTimeout</H1
><DIV
CLASS="REFNAMEDIV"
><A
NAME="AEN8393"
></A
><H2
>Name</H2
>SDL_CondWaitTimeout -- Wait on a condition variable, with timeout</DIV
><DIV
CLASS="REFSYNOPSISDIV"
><A
NAME="AEN8396"
></A
><H2
>Synopsis</H2
><DIV
CLASS="FUNCSYNOPSIS"
><A
NAME="AEN8397"
></A
><P
></P
><PRE
CLASS="FUNCSYNOPSISINFO"
>#include "SDL.h"
#include "SDL_thread.h"</PRE
><P
><CODE
><CODE
CLASS="FUNCDEF"
>int <B
CLASS="FSFUNC"
>SDL_CondWaitTimeout</B
></CODE
>(SDL_cond *cond, SDL_mutex *mutex, Uint32 ms);</CODE
></P
><P
></P
></DIV
></DIV
><DIV
CLASS="REFSECT1"
><A
NAME="AEN8403"
></A
><H2
>Description</H2
><P
>Wait on the condition variable <TT
CLASS="PARAMETER"
><I
>cond</I
></TT
> for, at most, <TT
CLASS="PARAMETER"
><I
>ms</I
></TT
> milliseconds. <TT
CLASS="PARAMETER"
><I
>mut</I
></TT
> is unlocked so it must be locked when the function is called. Returns <TT
CLASS="LITERAL"
>SDL_MUTEX_TIMEDOUT</TT
> if the condition is not signalled in the allotted time, <SPAN
CLASS="RETURNVALUE"
>0</SPAN
> if it was signalled or <SPAN
CLASS="RETURNVALUE"
>-1</SPAN
> on an error.</P
></DIV
><DIV
CLASS="REFSECT1"
><A
NAME="AEN8412"
></A
><H2
>See Also</H2
><P
><A
HREF="sdlcondwait.html"
><TT
CLASS="FUNCTION"
>SDL_CondWait</TT
></A
></P
></DIV
><DIV
CLASS="NAVFOOTER"
><HR
ALIGN="LEFT"
WIDTH="100%"><TABLE
SUMMARY="Footer navigation table"
WIDTH="100%"
BORDER="0"
CELLPADDING="0"
CELLSPACING="0"
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
><A
HREF="sdlcondwait.html"
ACCESSKEY="P"
>Prev</A
></TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="index.html"
ACCESSKEY="H"
>Home</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
><A
HREF="time.html"
ACCESSKEY="N"
>Next</A
></TD
></TR
><TR
><TD
WIDTH="33%"
ALIGN="left"
VALIGN="top"
>SDL_CondWait</TD
><TD
WIDTH="34%"
ALIGN="center"
VALIGN="top"
><A
HREF="thread.html"
ACCESSKEY="U"
>Up</A
></TD
><TD
WIDTH="33%"
ALIGN="right"
VALIGN="top"
>Time</TD
></TR
></TABLE
></DIV
></BODY
></HTML
>