// Copyright (c) 2006-2009 Nokia Corporation and/or its subsidiary(-ies).
// All rights reserved.
// This component and the accompanying materials are made available
// under the terms of the License "Eclipse Public License v1.0"
// which accompanies this distribution, and is available
// at the URL "http://www.eclipse.org/legal/epl-v10.html".
//
// Initial Contributors:
// Nokia Corporation - initial contribution.
//
// Contributors:
//
// Description:
// e32test\dll\t_oeexport_wins.cpp
// Overview:
// Emulator version that tests it is possible to retrieve the 0th
// ordinal from exes and dlls that are marked as having named
// symbol export data.
// API Information:
// RProcess, RLibrary
// Details:
// - Test reading 0th ordinal from a dll which has a E32EmulExpSymInfoHdr
// struct at the 0th ordinal and verify the contents of the header
// - Test NULL is returned on attempts to get the 0th ordinal from a
// dll without the named symbol data
// - Test reading the named symbol data from an exe that contains a
// E32EmulExpSymInfoHdr struct at the 0th ordinal and verify the contents
// - Test NULL is returned when attempting to read the 0th ordinal of
// an exe that doesn't contain a E32EmulExpSymInfoHdr
// Platforms/Drives/Compatibility:
// All
// Assumptions/Requirement/Pre-requisites:
// Failures and causes:
// Base Port information:
//
//
#include <t_oedll.h>
#include <e32test.h>
#include <e32panic.h>
#include <f32image.h>
RTest test(_L("T_OEEXPORT"));
LOCAL_D void VerifyHdr(E32EmulExpSymInfoHdr& aExpectedHdr, E32EmulExpSymInfoHdr &aReadHdr)
{
test(aExpectedHdr.iSymCount == aReadHdr.iSymCount);
test(aExpectedHdr.iDllCount == aReadHdr.iDllCount);
}
TInt E32Main()
{
test.Title();
test.Start(_L("Test retrieving 0th ordinal and therefore named symbol export data"));
E32EmulExpSymInfoHdr tmpHdr;
E32EmulExpSymInfoHdr *readHdr;
RLibrary library;
// The values for the header of the dll with a 0th ordinal
tmpHdr.iSymCount = 0x0;
tmpHdr.iDllCount = 0x3;
test(library.Load(_L("t_oedll.dll")) == KErrNone);
test.Next(_L("Attempt to retrieve named symbol data from t_oedll.dll"));
readHdr = (E32EmulExpSymInfoHdr*)library.Lookup(0);
test(readHdr!=NULL);
//#define PRINT_ZEROTH
#ifdef PRINT_ZEROTH
test.Printf(_L("iSymCount=%08x;iDllCounts=%08x\n"),readHdr->iSymCount,readHdr->iDllCount);
#endif
test.Next(_L("Verify export data of t_oedll.dll is that expected"));
VerifyHdr(tmpHdr, *readHdr);
library.Close();
test.Next(_L("Verify lookup on dll without oe export data returns NULL"));
test(library.Load(_L("t_dll1.dll")) == KErrNone);
readHdr = (E32EmulExpSymInfoHdr*)library.Lookup(0);
test(readHdr == NULL);
library.Close();
// The values for the header of the exe of the current process with a 0th ordinal
tmpHdr.iSymCount = 0x3;
tmpHdr.iDllCount = 0x5;
test.Next(_L("Attempt to retrieve named symbol data from current process"));
readHdr = (E32EmulExpSymInfoHdr*)(RProcess::ExeExportData());
test(readHdr!=NULL);
test.Next(_L("Verify export data 0th ordinal data of this exe is that expected"));
#ifdef PRINT_ZEROTH
test.Printf(_L("iSymCount=%08x;iDllCounts=%08x;\n"),readHdr->iSymCount,readHdr->iDllCount);
#endif
VerifyHdr(tmpHdr, *readHdr);
/*
On Emulator can't examine fixups & depdencies via export data as data not included
in E32EmulExpSymInfoHdr. This is all handled by the MS loader.
*/
test.End();
return KErrNone;
}