* Copyright (c) 2010 Nokia Corporation and/or its subsidiary(-ies).
* All rights reserved.
* This component and the accompanying materials are made available
* under the terms of "Eclipse Public License v1.0"
* which accompanies this distribution, and is available
* at the URL "http://www.eclipse.org/legal/epl-v10.html".
*
* Initial Contributors:
* Nokia Corporation - initial contribution.
*
* Contributors:
*
* Description:
*
*/
/** @file
@brief USB charging information header
@version 0.2.0
This header specifies the published information of USB charging plug-in.
@publishedPartner
*/
#ifndef USBCHARGINGPUBLISHEDINFO_H
#define USBCHARGINGPUBLISHEDINFO_H
#include <e32base.h>
/** this is only applicable when charging port is a Standard Downstream Port
*/
enum TUsbConnectionStatus
{
/** this is the initial value. */
EUsbConnectionStatusNone,
/** This status means that this USB device is in suspend state. */
EUsbConnectionStatusSuspend,
/** This status means that this USB device is in configured state. */
EUsbConnectionStatusConfigured
};
enum TUsbChargingPortType
{
/**
* This device is no longer connected to a powered port.
* iMinAvailableVbusCurrent, iMaxVbusCurrent and iMinVbusVoltage are 0.
* iUsbConnStatus is EUsbConnectionStatusNone.
*/
EUsbChargingPortTypeNone = 0,
/**
* This device is connected to a port that can't be recognized.
* iMinAvailableVbusCurrent, iMaxVbusCurrent and iMinVbusVoltage are 0.
* iUsbConnStatus is EUsbConnectionStatusNone.
*/
EUsbChargingPortTypeUnsupported,
/**
* This device is connected to a charging port.
* This is not an exact port type and the port may be a dedicated charging port or a charging downstream port.
* For there is more constraint on charging downstream port output, current and voltage are computed according
* to charging downstream port.
* See below for detail.
*/
EUsbChargingPortTypeChargingPort,
/**
* This device is connected to a dedicated charging port.
* iMinAvailableVbusCurrent is 500mA (refer to min IDCHG in table 5-2 of BC1.1).
* iMaxVbusCurrent is 1800mA (refer to IDEV_DCHG in table 5-2 of BC1.1).
* iMinVbusVoltage is 2000mV ( refer to VCHG_SHT_DWN in table 5-1 of BC1.1).
* iUsbConnStatus is EUsbConnectionStatusNone.
*/
EUsbChargingPortTypeDedicatedChargingPort,
/**
* This device is connected to a charging downstream port.
* - If this device works at low speed or full speed mode.
* - iMinAvailableVbusCurrent is 500mA (refer to min IDCHG in table 5-2 of BC1.1).
* - iMaxVbusCurrent is 1500mA (refer to IDEV_HCHG_LFS in table 5-2 of BC1.1).
* - iMinVbusVoltage is 2000mV (refer to VCHG_SHT_DWN in table 5-1 of BC1.1).
* - iUsbConnStatus is EUsbConnectionStatusNone.
*
* - If this device works at high speed.
* - if USB hardware supports current limit when chirping.
* - iMinAvailableVbusCurrent is 500mA (refer to min IDCHG in table 5-2 of BC1.1).
* - iMaxVbusCurrent is 900mA (refer to IDEV_HCHG_HS in table 5-2 of BC1.1).
* - iMinVbusVoltage is 2000mV (refer to VCHG_SHT_DWN in table 5-1 of BC1.1).
* - iUsbConnStatus is EUsbConnectionStatusNone
* - if USB hardware does not support current limit when chirping
* - iMinAvailableVbusCurrent is 500mA (refer to min IDCHG in table 5-2 of BC1.1).
* - iMaxVbusCurrent is 560mA (refer to IDEV_HCHG_CHRP in table 5-2 of BC1.1).
* - iMinVbusVoltage is 2000mV (refer to VCHG_SHT_DWN in table 5-1 of BC1.1).
* - iUsbConnStatus is EUsbConnectionStatusNone.
*/
EUsbChargingPortTypeChargingDownstreamPort,
/** This device is connected to a standard downstream port.
* This device negoiates the charging current with standard host by configuration descriptor. There are three numbers of
* milliamps that can be negoiated, 500mA, 100mA and 8mA.
* - if any of the three numbers is acceptted by host.
* - if this device is in configured state.
* - iMinAvailableVbusCurrent and iMaxVbusCurrent are 500mA or 100mA or 8mA.
* - iUsbConnStatus is EUsbConnectionStatusConfigured.
* - if this device is in suspend state.
* - iMinAvailableVbusCurrent and iMaxVbusCurrent are 2mA (refer to ISUSP in table 5-2 of BC1.1).
* - iUsbConnStatus is EUsbConnectionStatusSuspend.
* - iMinVbusVoltage is 4500mV in both cases. 4.5 V comes from the port supply requirement 4.75 V with the worst case
* voltage drops for 500 mA current taken into account. That is: 4.75 V - VGNDD - VBUSD = 4.75 V - 0.125 V - 0.125 V = 4.5 V.
* See Section 7.2.2 Voltage Drop Budget in USB 2.0 spec.
*
* - if none of the three numbers is acceptted by host.
* - iMinAvailableVbusCurrent, iMaxVbusCurrent and iMinVbusVoltage are 0 and iUsbConnStatus is EUsbConnectionStatusNone.
*/
EUsbChargingPortTypeStandardDownstreamPort,
/** This device is connected to an ACA and ID pin status is RidA.
* When ID pin status is RidA, this device works as A-device and is connected to an ACA. The ACA is connected with a charger
* or a charging downstream port on ACA's charging port and may be connected to a B-device on ACA's accessory port.
* The B-device can draw current from the charger.
* iMinAvailableVbusCurrent is not more than 500mA. This value comes from 500mA (min IDCHG refer to in table 5-2 of BC1.1) minus the current that B-device
* can draw. This value is maxpower field of B-device configuration descriptor. If there is no connected B-device, minus 0 from 500mA.
* iMaxVbusCurrent is 1500mA (refer to max IDCHG in table 5-2 of BC1.1). For ACA can't distinguish a charger and a charging downstream
* port so we select more contraint output.
* iMinVbusVoltage is 2000mV (refer to VCHG_SHT_DWN in table 5-1 of BC1.1).
* iUsbConnStatus is EUsbConnectionStatusNone.
*/
EUsbChargingPortTypeAcaRidA,
/** This device is connected to an ACA and ID pin status is RidB
* When ID pin status is RidB, this device works as a B-device and is connected to an ACA. The ACA is connected with a charger or a
* charging downstream port on ACA's charging port. ACA may also be connected to A-device on accessory port but A-device VBUS
* powers off. A-device shall not draw current from the accessory port.
* iMinAvailableVbusCurrent is 500mA (refer to min IDCHG in table 5-2 of BC1.1).
* iMaxVbusCurrent is 1500mA (refer to max IDCHG in table 5-2 of BC1.1).
* iMinVbusVoltage is 2000mV (refer to VCHG_SHT_DWN in table 5-1 of BC1.1).
* iUsbConnStatus is EUsbConnectionStatusNone.
*/
EUsbChargingPortTypeAcaRidB,
/** This device is connected to an ACA and ID pin status is RidC
* When ID pin status is RidC, this device work as a B-device and is connected to an ACA. The ACA is connected with a charger or
* a charging downstream port on ACA's charging port and a A-device on accessory port. The A-device VBus powers on. A-device
* shall not draw current from accessory port.
* iMinAvailableVbusCurrent is 500mA (refer to min IDCHG in table 5-2 of BC1.1).
* iMaxVbusCurrent is 1500mA (refer to max IDCHG in table 5-2 of BC1.1).
* iMinVbusVoltage is 2000mV (refer to VCHG_SHT_DWN in table 5-1 of BC1.1).
* iUsbConnStatus is EUsbConnectionStatusNone.
*/
EUsbChargingPortTypeAcaRidC
};
/**
* the P&S key category of published charing information.
*/
const TUid KPropertyUidUsbBatteryChargingCategory = {0x101fe1db};
/**
* the P&S key ID of published charing information.
*/
const TUint KPropertyUidUsbBatteryChargingInfo = 1;
/**
* the structure of published charing information, data in P&S is a TPckgBuf wrappering this structure
*/
NONSHARABLE_STRUCT(TPublishedUsbChargingInfo)
{
/** the port type this device connects to. */
TUsbChargingPortType iChargingPortType;
/** this field is only appliable when this device connects to a standard downstream port. */
TUsbConnectionStatus iUsbConnStatus;
/**
* This is the number of milliamps in unit 1 mA that can safely be drawn from VBUS
* without needing to observe the VBUS level.
*/
TUint16 iMinAvailableVbusCurrent;
/**
* This is the number of milliamps that can be drawn from VBus in unit 1 mA. VBUS Level may drop down and must be monitored
* to prevent VBUS Level drop below iMaxVbusCurrent.
*/
TUint16 iMaxVbusCurrent;
/** VBUS Level must be above this number when charging and this number is in unit 1 mV. */
TUint16 iMinVbusVoltage;
};
#endif // USBCHARGINGPUBLISHEDINFO_H