<?xml version="1.0" encoding="utf-8"?>
<!-- Copyright (c) 2007-2010 Nokia Corporation and/or its subsidiary(-ies) All rights reserved. -->
<!-- This component and the accompanying materials are made available under the terms of the License 
"Eclipse Public License v1.0" which accompanies this distribution, 
and is available at the URL "http://www.eclipse.org/legal/epl-v10.html". -->
<!-- Initial Contributors:
    Nokia Corporation - initial contribution.
Contributors: 
-->
<!DOCTYPE concept
  PUBLIC "-//OASIS//DTD DITA Concept//EN" "concept.dtd">
<concept id="GUID-B0D76734-1DB7-5465-91AE-BB3521599A75" xml:lang="en"><title>Log
Engine Tutorial Overview</title><prolog><metadata><keywords/></metadata></prolog><conbody>
<p>This overview provides the information to perform various tasks that clients
perform with Log Engine. </p>
<section id="GUID-976D4359-6836-5501-8C53-1C2B0E577160"><title>Purpose</title> <p>The
log engine stores events generated by operating system components, particularly
telephony and messaging. This document explains how to use the log engine
to create a record of events and how to create views of the events for display. </p> </section>
<section id="GUID-61FEA51A-D091-59D7-A645-8E008E3A7C3E"><title>Introduction</title> <p>The
log engine uses a client-server architecture. The log server is a permanent
process maintaining event data and the log clients attach to it to add and
retrieve data. When writing an application which uses the log engine you create
a log client wrapped in a customized component. This component has two purposes.
Firstly it causes the server to log events of a specified kind. Secondly it
uses log filter and log view classes to extract and present the data appropriately. </p> <p>The
log engine is designed to abstract from the details of how events are notified,
stored and displayed. You do not need to know exactly how this functionality
is implemented. </p> <p>The log engine is an interface to a database holding
records of communication events. You do not need to know the implementation
of the database, merely that the log engine has functionality to add, read,
modify and delete records. </p> <p>Not all devices are equipped with logging
functionality. You need to determine whether your application will only run
on platforms with logging functionality guaranteed or else write the application
so as to fail gracefully. For this reason the class <xref href="GUID-51C67545-12BA-326D-BD8F-662B24C68ED2.dita"><apiname>CLogClient</apiname></xref> and
its parent class <xref href="GUID-4A7D312F-A8C6-3663-8455-13FA73F1CFB5.dita"><apiname>CLogBase</apiname></xref> are often wrapped in a class <xref href="GUID-146D719E-BDD6-3F20-80B1-EDE09081A6EA.dita"><apiname>CLogWrapper</apiname></xref> which
handles cases where logging functionality is absent. </p> <p>Logging calls
are asynchronous. The application developer is responsible for maintaining
the integrity of the log client session. A typical way of doing this is to
maintain a queue of log events. </p> <p>The log engine provides limited configuration
functionality. If you are involved in device creation and want to tune performance
you need to know how to manage memory and configure the logging component
explicitly: the topic is not covered in this document. </p> <p>The log engine
models standard types of communication event by default. If your application
involves non-standard functionality you need to know how to create user defined
data types to represent non-standard events. </p> <p>The log engine uses the
Symbian platform capabilities model of security. This means that your application
must police its own security and you must therefore know the security capabilities
required by each item of functionality. </p> <p>The purpose of the log engine
is to provide data for a viewer application which displays information such
as missed calls to the end user of the device. You do not need to know anything
about the viewer, merely that it requires data views to be provided in certain
data structures. </p> <p>The log engine gets updated by an observer component
which notifies it of new communication events affecting either the data tables
or the views created from them. You do not need to know the details of the
interprocess communication, merely that an observer component exists and performs
notifications. </p> </section>
<section id="GUID-F0F5CEB4-7BFD-5C7E-AEAE-B9A5EAC306B3"><title>Log clients
and log views</title> <p>The log engine API consists of two types of classes,
the client classes and the view classes. The client classes exist to create
logs and maintain and modify them. They are <xref href="GUID-51C67545-12BA-326D-BD8F-662B24C68ED2.dita"><apiname>CLogClient</apiname></xref>, <xref href="GUID-4A7D312F-A8C6-3663-8455-13FA73F1CFB5.dita"><apiname>CLogBase</apiname></xref> and <xref href="GUID-146D719E-BDD6-3F20-80B1-EDE09081A6EA.dita"><apiname>CLogWrapper</apiname></xref>.
It is <xref href="GUID-51C67545-12BA-326D-BD8F-662B24C68ED2.dita"><apiname>CLogClient</apiname></xref> which contains the actual functionality:
the purpose of <xref href="GUID-4A7D312F-A8C6-3663-8455-13FA73F1CFB5.dita"><apiname>CLogBase</apiname></xref> and <xref href="GUID-146D719E-BDD6-3F20-80B1-EDE09081A6EA.dita"><apiname>CLogWrapper</apiname></xref> is
to provide default functionality when logging functionality is not available.
The view classes exist to filter the log data and prepare it for presentation
in a viewer application. They are <xref href="GUID-3A3E6F09-0F78-38E1-95F5-00C743F41073.dita"><apiname>CLogViewEvent</apiname></xref> and <xref href="GUID-F40F9556-F223-36A5-9812-6EF6FF3F5156.dita"><apiname>CLogViewRecent</apiname></xref>,
which inherit from a class <xref href="GUID-F33ADAF2-FD57-3662-B3AC-1000B69289D6.dita"><apiname>CLogView</apiname></xref> which cannot be instantiated. </p> </section>
<section id="GUID-D511597A-013F-5ECA-97C5-A75770575EFF"><title>Events and
event types</title> <p>The log engine is designed to log events having to
do with communications: messaging, telephony, email and so on. The class <xref href="GUID-CDFB61A7-1C74-3F63-9FDF-5A3B8603A010.dita"><apiname>CLogEvent</apiname></xref> represents
events of this kind: its member objects mainly have to do with types of communication.
The class <xref href="GUID-E7CCB043-770E-3722-B735-92B65CC7A0D8.dita"><apiname>CLogEventType</apiname></xref> contains information about the
event type which a particular event belongs to. </p> <p><b>Log
events</b> </p> <p>The <xref href="GUID-CDFB61A7-1C74-3F63-9FDF-5A3B8603A010.dita"><apiname>CLogEvent</apiname></xref> class encapsulates data
about communication events. </p> <ul>
<li id="GUID-0B904A94-48BE-5534-81C0-B3103B33EA06"><p>The ID is the unique
identifier of the event. </p> </li>
<li id="GUID-FC68C424-C8B8-51AC-96E0-498C59AEB905"><p>The remote party is
the device originating or receiving the communication. </p> </li>
<li id="GUID-E362093C-3618-5EF6-977C-9FA6FA9384EA"><p>The direction indicates
whether the communication is incoming or outgoing. </p> </li>
<li id="GUID-1007760C-A467-5697-8F5D-5EE586959B66"><p>The time of the event
is the time at which it began. </p> </li>
<li id="GUID-3D3A7537-1F54-5F36-AFD1-1B6D29B236E2"><p>The duration type is
one of three constants: <xref href="GUID-8ADA7A0F-0A96-3B80-B09F-F01ACA7CB51C.dita"><apiname>KLogDurationNone</apiname></xref>, <xref href="GUID-F9F30026-EBA8-334C-B926-95886F9D0B82.dita"><apiname>KLogDurationData</apiname></xref> or <xref href="GUID-8F476C11-5DEA-3690-84D2-F3C56A5ECDEE.dita"><apiname>KLogDurationValid</apiname></xref>.
You typically use them where the event being represented either has no duration,
or has a duration of no relevance (such as a data transfer), or has a valid
duration (such as a voice call). </p> </li>
<li id="GUID-6184A320-07E4-5968-B92E-79619C4593ED"><p>The duration is the
duration in seconds from the start of the event to the end. </p> </li>
<li id="GUID-79D55852-1670-540D-901C-54EF22DC0A80"><p>The delivery status
is one of a set of flags indicating whether the communication was successfully
delivered. </p> </li>
<li id="GUID-FF64F139-E294-5D35-97D5-FCDB41FF56AC"><p>The subject is a string
to be displayed in the subject line of the viewer application. </p> </li>
<li id="GUID-2F387309-992C-5E97-9C11-D579E2786E00"><p>The log link is the
ID of the event in the calling application, as distinct from its ID in the
log. </p> </li>
<li id="GUID-D14F2BB8-EE85-57AE-B8C1-F5CEB0E039CF"><p>The description is a
human readable description of the event type. </p> </li>
<li id="GUID-485D6CB5-1433-5A4A-B9F6-2292F05BD878"><p>There is only one flag, <xref href="GUID-D593DD54-B0A6-38A2-BC17-5D4542343A67.dita"><apiname>KLogEventRead</apiname></xref>,
which is set to true if the event has been read by a client. It can be cleared
either by passing the constant <xref href="GUID-1FB349A5-F3D2-3D75-BB6A-9BA3AD1F30B6.dita"><apiname>KLogFlagsMask</apiname></xref> to the function <xref href="GUID-E6477727-53AA-3092-AB4E-54E2EC50C891.dita"><apiname>SetFlags()</apiname></xref> or
by calling the function <xref href="GUID-AD7C319E-5ACA-3D1C-B000-AD45B388FA4E.dita"><apiname>ClearFlags()</apiname></xref>. </p> </li>
</ul> <p><b>Log
event types</b> </p> <p>The log engine API defines constants of type <xref href="GUID-530281E6-29FC-33F2-BC9B-610FBA389444.dita"><apiname>TUid</apiname></xref> representing
the standard types of communication event which can be logged. </p> <ul>
<li id="GUID-DCCB5455-5251-5394-8E36-BB0493D230A2"><p> <xref href="GUID-5A0DEBDD-EE90-336A-8990-0C8E65D87B8D.dita"><apiname>KLogCallEventType</apiname></xref>:
voice call </p> </li>
<li id="GUID-345EF3F1-9FAA-530F-B13E-086333EB16B2"><p> <xref href="GUID-95C9EA37-216C-3012-8579-D27EDE985F37.dita"><apiname>KLogDataEventType</apiname></xref>:
data call </p> </li>
<li id="GUID-95B204BD-D1CD-528D-BCE4-2202C8B6C70A"><p> <xref href="GUID-1F4D6F37-7095-37D1-9CFD-4C612854F1D9.dita"><apiname>KLogFaxEventType</apiname></xref>:
fax call </p> </li>
<li id="GUID-D7A6070F-96ED-57B0-B4AC-16BD30182EEB"><p> <xref href="GUID-9939CC72-09CF-3AAE-A7B7-BCA1FC036BB7.dita"><apiname>KLogShortMessageEventType</apiname></xref>:
SMS call </p> </li>
<li id="GUID-355B1AF2-403D-5EF7-9656-E526E5C9FFAA"><p> <xref href="GUID-95E66461-EBD7-3843-AD05-D632AB113F2A.dita"><apiname>KLogMailEventType</apiname></xref>:
email </p> </li>
<li id="GUID-95FC2F4A-0D7F-5378-AF50-38F40440347F"><p> <xref href="GUID-EA11EA32-F6A1-3C57-8C20-98E9D98F5ED8.dita"><apiname>KLogTaskSchedulerEventType</apiname></xref>:
task scheduler event </p> </li>
</ul> <p>The log engine API provides the class <xref href="GUID-E7CCB043-770E-3722-B735-92B65CC7A0D8.dita"><apiname>CLogEventType</apiname></xref> which
acts on all events of a specified type. Its functions are: </p> <ul>
<li id="GUID-06AFACB8-A994-5A60-BD35-35D1054118FD"><p> <xref href="GUID-260722ED-60D9-37EB-A95C-6F0BF4692D97.dita"><apiname>Uid()</apiname></xref> and <xref href="GUID-05D6F7AA-878A-32D6-BD81-C8D30838FB71.dita"><apiname>SetUid()</apiname></xref> get
and set the UID identifying the event type. </p> </li>
<li id="GUID-480DAE38-65A8-52A1-ADCF-6B70ED1D08F4"><p> <xref href="GUID-E7339978-FFE8-3C38-818A-FEE7CBDAE34A.dita"><apiname>Description()</apiname></xref> and <xref href="GUID-37D64FF2-A036-3511-B7B3-54BC33DF0805.dita"><apiname>SetDescription()</apiname></xref> get
and set the description in words of the event type. </p> </li>
<li id="GUID-B6C7ACBC-080D-5295-8E1B-E0DCA546F3E2"><p> <xref href="GUID-D498B4D9-7106-396F-B750-CB7BFAB26851.dita"><apiname>LoggingEnabled()</apiname></xref> and <xref href="GUID-E366A706-736E-3530-88B3-26727B8D9C17.dita"><apiname>SetLoggingEnabled()</apiname></xref> get
and set a flag which enables events of this type to be logged. </p> </li>
<li id="GUID-F2C2D7A2-A0DE-59D3-BD25-0D794D7566F1"><p> <xref href="GUID-CD3C9BD5-1386-3CF5-A8F6-9BE1AE40689F.dita"><apiname>Copy()</apiname></xref> copies
an existing event type. </p> </li>
<li id="GUID-EB4393F4-02E7-5422-85C0-7B3FEC0D2D6A"><p> <xref href="GUID-B677E528-7C32-3483-8B30-F1CDC6875B03.dita"><apiname>InternaliseL()</apiname></xref> and <xref href="GUID-0304F040-A7C1-3911-ACA3-6A75FBDB8ACF.dita"><apiname>ExternaliseL()</apiname></xref> implement
streaming input and output of an event type object. </p> </li>
</ul> <p>You may need an event type not supplied with the log engine API,
for instance if you are developing a new kind of messaging application. A
new event type requires a new unique Id which must be allocated by Symbian
Signed. Once you have that Id you can create a <xref href="GUID-E7CCB043-770E-3722-B735-92B65CC7A0D8.dita"><apiname>CLogEventType</apiname></xref> and
pass the Id to <xref href="GUID-05D6F7AA-878A-32D6-BD81-C8D30838FB71.dita"><apiname>SetUid()</apiname></xref> just like the standard event type
constants. </p> <p>The main use of <xref href="GUID-E7CCB043-770E-3722-B735-92B65CC7A0D8.dita"><apiname>CLogEventType</apiname></xref> is to
enable or disable logging for all events of a particular type. You do this
by creating a <xref href="GUID-E7CCB043-770E-3722-B735-92B65CC7A0D8.dita"><apiname>CLogEventType</apiname></xref> object with its UID set to
the relevant event type and calling its <xref href="GUID-E366A706-736E-3530-88B3-26727B8D9C17.dita"><apiname>SetLoggingEnabled()</apiname></xref> function
with <xref href="GUID-781E8158-805B-3784-8FED-D7A191822FC3.dita"><apiname>ETrue</apiname></xref> or <xref href="GUID-A759CA2D-8327-348F-9337-4886E619D920.dita"><apiname>EFalse</apiname></xref> as argument. </p> <p>It
is important to know that only an explicit call to the <xref href="GUID-E366A706-736E-3530-88B3-26727B8D9C17.dita"><apiname>SetLoggingEnabled()</apiname></xref> function
of a <xref href="GUID-E7CCB043-770E-3722-B735-92B65CC7A0D8.dita"><apiname>CLogEventType</apiname></xref> object will cause logging to take place.
For instance if you create a new event type <xref href="GUID-C2D1CC20-9AF0-3B02-B42B-BE96534F44DE.dita"><apiname>myEventType</apiname></xref> and
want such events to be logged, you have to call its <xref href="GUID-E366A706-736E-3530-88B3-26727B8D9C17.dita"><apiname>SetLoggingEnabled()</apiname></xref> function
before logging will occur. </p> <codeblock id="GUID-F3C05730-5CB0-51A0-8975-311D64C21213" xml:space="preserve">    CLogEventType* myEventType = CLogEventType::NewL();myEventType-&gt;SetLoggingEnabled(ETrue);</codeblock> </section>
<section id="GUID-5CE676D6-7F07-5C37-99F7-A17C2FC9185C"><title>Log engine
and platform security</title> <p>The Symbian platform uses a capabilities
model of security in which an application being called verifies that the calling
application has the required security policies before returning data. This
is important in connection with message logging which involves the end user's
confidential information. When writing an application which incorporates logging
functionality you must ensure that it has the capabilities to call the log
engine APIs. </p> <p>To call a log client, a calling application must have
the capabilities required by the event type of the event being accessed. This
means that a call to <xref href="GUID-51C67545-12BA-326D-BD8F-662B24C68ED2.dita#GUID-51C67545-12BA-326D-BD8F-662B24C68ED2/GUID-034027BA-BD4B-331B-8F1D-1B5750FD2BCD"><apiname>CLogClient::GetEvent()</apiname></xref> must have the
capability specified in the read policy of the event type, while calls to <xref href="GUID-91804418-6DCC-3ACF-BA1E-399B112285A3.dita"><apiname>AddEvent()</apiname></xref>, <xref href="GUID-C8F2B567-6B68-3460-9799-6658DF3771A8.dita"><apiname>ChangeEvent()</apiname></xref> and <xref href="GUID-EC15284E-B1CF-3DB6-87C1-E639F270E434.dita"><apiname>DeleteEvent()</apiname></xref> must have the capability specified in the write policy.
To modify the event type by calling <xref href="GUID-1AC902E9-EAE0-329A-A69E-6823A317DEE8.dita"><apiname>AddEventType()</apiname></xref>, <xref href="GUID-966DB6EC-CE70-3F08-A4D1-30F76AF5A54F.dita"><apiname>ChangeEventType()</apiname></xref> and <xref href="GUID-FA3CA920-0F43-3B7C-8171-905BC8C8C2A4.dita"><apiname>DeleteEventType()</apiname></xref> a calling application requires the <xref href="GUID-7BA52F1C-159D-3F72-91A3-1A2B5870C48B.dita"><apiname>WriteDeviceData</apiname></xref> capability.
No capability is required to call <xref href="GUID-BF3481A7-85D0-3431-81C8-905FF0D40887.dita"><apiname>GetEventType()</apiname></xref>. </p> <p>No
security capability is required to access the view classes. </p> </section>
<section id="GUID-4B5E20B7-5689-5AB1-B265-9C9956B32635"><title>Using filters
when displaying a log</title> <p>An event view typically contains only a selection
of items from the main log which satisfy the constraints of a filter. A <xref href="GUID-99144BA6-F79A-3D3C-B1D3-272B3723C42C.dita"><apiname>CLogFilter</apiname></xref> has
members representing the same information as a <xref href="GUID-CDFB61A7-1C74-3F63-9FDF-5A3B8603A010.dita"><apiname>CLogEvent</apiname></xref> object
but is used to select on data not modify it. (In the database implementation,
a filter corresponds to the WHERE clause of a SELECT query.) An event view
is empty when created. To initialize it you first create and initialize a <xref href="GUID-99144BA6-F79A-3D3C-B1D3-272B3723C42C.dita"><apiname>CLogFilter</apiname></xref> object
and then pass this as a parameter of the <xref href="GUID-409E06DF-141C-3352-8E31-87646F9C2DCA.dita"><apiname>SetFilterL()</apiname></xref> function
of the event view. You may also want to initialize a view to satisfy any one
of several filters, in which case you pass in a <xref href="GUID-84D55725-6357-3596-B1DE-3F3388884504.dita"><apiname>CLogFilterList</apiname></xref>:
this is an array of several <xref href="GUID-99144BA6-F79A-3D3C-B1D3-272B3723C42C.dita"><apiname>CLogFilter</apiname></xref> objects. You would
do this, for instance, if you wanted to create a view to display events of
several different event types such as voice mail, SMS and email, since a single <xref href="GUID-99144BA6-F79A-3D3C-B1D3-272B3723C42C.dita"><apiname>CLogFilter</apiname></xref> only
has one event type. </p> </section>
<section id="GUID-695967C7-72D9-4026-B719-A756CB89060B"><ol id="GUID-DB02C018-8542-5E49-AB88-44708F78AF3F">
<li id="GUID-0A180E8B-8D5F-5C74-BCF3-24F5387B3F73"><p><xref href="GUID-BCB0E50F-B22E-5964-BB68-BEE1870D9C79.dita">Configuring
Log Engine </xref>  </p> <p>The clients must configure the Log Engine before
using it. </p> </li>
<li id="GUID-5920F750-32FE-537B-90E1-AA9A5814FF01"><p><xref href="GUID-2022F702-9899-5798-8932-D70119C7177D.dita">Setting
Up A Log Engine Client</xref>  </p> <p>After configuring the log engine, a
log engine client must be developed. </p> </li>
<li id="GUID-2449AFDC-998A-51CF-A81C-B9209445895C"><p><xref href="GUID-E4A950EA-5671-5755-B3EF-5D6B90E19AE6.dita">Maintaining
Log Events</xref>  </p> <p>The client applications can then add event, event
types and delete if necessary. </p> </li>
<li id="GUID-B87FA355-BD1B-5595-8FD5-008D281A5D6A"><p><xref href="GUID-BE65B3A7-04E8-5406-B46A-09E2608E0F1F.dita">Requesting
Log Engine Notifications</xref> </p> <p>Client applications can receive notification
from log engine to get events recorded by other applications. </p> </li>
<li id="GUID-5E27A02E-D120-5410-A1F6-54909E9F8324"><p><xref href="GUID-55ECBCF5-FC29-5A4A-A3C6-1CB1C0D562CE.dita">Displaying
Log Events</xref>  </p> <p>Finally the client applications can then display
the log events to the user. </p> </li>
</ol> </section>